Heures de service : Lundi à vendredi 9h00-18h00
3VA6560-7KQ32-2AA0 - 3VA6560-7KQ32-2AA0 SIEMENS Circuit breaker 3VA6 UL Frame 800 breaking capacity class C 100kA @ 480 V 3-pole,..
En stock Produit phare

3VA6560-7KQ32-2AA0

3VA6560-7KQ32-2AA0 SIEMENS Circuit breaker 3VA6 UL Frame 800 breaking capacity class C 100kA @ 480 V 3-pole,..

$0.00USD
4450 en stock
Spécifications clés
:
EAN:4042949437697
CEM:Declaration of Conformity
UPC:804766981197
Informations sur le fournisseur
SIEMENS
SIEMENS
Produits : 367174
Habituellement expédié sous 2 à 3 jours ouvrables
Qualité garantie
Livraison rapide
Support technique

Spécifications techniques

ParamètreValeur
EAN4042949437697
CEMDeclaration of Conformity
UPC804766981197
ETIM7
IDÉE4
profondeur120 mm
autreDangerous Good
largeur210 mm
UNSPSC15
eClass12
hauteur328 mm
Code de groupeP360
Poids net12.76 kg
profondeur [en]4.72 in
largeur [en]8.27 in
hauteur [en]12.91 in
● maximum600 A
● minimum240 A
Confirmation
Facteur MétalLPB-----
● à 240 V200 kA
● à 415 V110 kA
● à 480 V100 kA
● à 600 V50 kA
● à 690 V35 kA
Date : 25/08/2023Subject to change without notice© Copyright Siemens 2023
Groupe de produits5383
Classe de produitsC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Unité de quantité1 Piece
● à 40 °C600 A
● à 45 °C600 A
● à 50 °C600 A
● à 55 °C600 A
● à 60 °C600 A
● à 65 °C555 A
● à 70 °C510 A
Code des produits85362090
Famille de produits3VA Molded Case Circuit Breakers up to 2000 A, UL / IEC
dernière modification :8/14/2023
Poids net (kg)12,760 Kg
nombre de pôles3
fonction du produit
Pays d'origineMexico
composant du produit
● valeur initiale120 A
LKZ_FDB/ CatalogIDLV10
Quantité d'emballage1
nom de marque du produitSENTRON
● indicateur de trajetNo
Dimensions de l'emballage250,00 x 360,00 x 180,00
Description du produitCircuit breaker 3VA6 UL Frame 800 breaking capacity class C 100kA @ 480 V 3-pole, Line protection ETU860, LSIG, In=600A overload protection, 100% rated Ir=240A ...600A Short-circuit protection Isd=0.6..12x In, Ii=1.5..12x In N conductor protection optionally with external CT up to 160% Ground-fault protection Ig=0.2... 1 x In, tg=0.05-0.8s
température ambiante
courant opérationnel
désignation du produitMolded-case circuit breaker
● Déclencheur de tensionNo
● valeur à pleine échelle600 A
conception du produitSystem protection
Cycle de vie du produit (PLM)PM300:Active Product
perte de puissance [W] / maximum151 W
● Déclenchement en cas de sous-tensionNo
capacité de coupure actuelle
Règlement sur le contrôle des exportationsAL : N / ECCN : EAR99
● fonction de communicationYes
Délai de livraison standard départ usine25 Day/Days
Surcharge pour matières premièresNone
Unité de mesure de la taille de l'emballageMM
● pendant le stockage / maximum80 °C
● pendant le stockage / minimum-40 °C
● pendant le fonctionnement / maximum70 °C
● pendant le fonctionnement / minimum-25 °C
● autre fonction de mesureYes
version de surveillance des défauts à la terreSummation current formation L-conductor
tension d'isolement / valeur nominale800 V
conception du dispositif de déclenchement de surintensitéETU860
Indice de protection IP / sur la face avantIP40
conception de la protection du conducteur Nadjustable OFF; 20% to 160%
Numéro d'article (Numéro destiné au marché)3VA6560-7KQ32-2AA0
Obligation de reprise des DEEE (2012/19/UE)Yes
tension de fonctionnement / en courant alternatif / valeur nominale690 V
Fonctionnement du produit / protection contre la mise à la terreYes
Code de référence / selon la norme IEC 81346-2Q
Désignation du produit / selon le fichier ULCMAE
extension de produit / optionnel / entraînement par moteurNo
capacité de court-circuit (Icm)
nombre de contacts CO / pour les contacts auxiliaires0
fonction de protection du disjoncteur de surintensitéLSIG
classe de capacité de coupure du disjoncteurC
Courant de réglage réglable (InN) / pour déclenchement N
endurance électrique (cycles de fonctionnement) / à 480 V5 100
endurance électrique (cycles de fonctionnement) / à 600 V3 500
Marquage / conforme à la norme UL 489 / disjoncteur à 100 %Yes
Groupe de prix spécifique à la région / Groupe de prix du siège social12P / 1CB
durée de vie mécanique (cycles de fonctionnement) / typique10 000
Capacité de coupure maximale du courant de court-circuit (Icu)
pouvoir de coupure du courant de court-circuit en fonctionnement (Ics)
type de connexion électrique / pour circuit de courant principalnut keeper kit on both ends
Délai réglable / de bande S / avec caractéristique I2t0.5 s
endurance électrique (cycles de fonctionnement) / à AC-1 / à 690 V3 500
valeur de réponse réglable, réglage du courant (Ii) / pour le déclenchement I
disposition des connecteurs électriques / pour circuit de courant principalFront connection
endurance électrique (cycles de fonctionnement) / à AC-1 / à 380/415 V5 100
Durée totale de pause / pour les G tripping / avec caractéristique standard
Conformité aux restrictions relatives aux substances conformément à la directive RoHSSince: 09.07.2019
Article 33 du règlement REACH : Obligation d’informer en fonction de la liste actuelle des candidatsLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Silicic acid, lead s... CAS-No. 11120-22-2 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Silicic acid, lead saltBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Perfluorobutane sulfonic ... > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Perfluorobutane sulfonic acid (PFBS) and its saltsBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
valeur de réponse en courant réglable courant / unité de déclenchement instantané en court-circuit
Délai de réponse réglable (tg) / pour déclenchement par G / avec caractéristique I0t
Délai de réponse réglable (tg) / pour déclenchement par G / avec caractéristique I2t
valeur de réponse réglable, temps de retard (tr) / pour déclenchement L / avec caractéristique I2t
Délai de réponse réglable (tsd) / pour le découplage en S / avec caractéristique I0t
Délai de réponse réglable (tsd) / pour le découplage en S / avec caractéristique I²t
Courant de réglage de la valeur de réponse ajustable (Isd) / de la bande S / avec caractéristique I0t
Courant de réglage de la valeur de réponse ajustable (Isd) / de la bande S / avec caractéristique I²t
certificat de convenance / approbation pour usage naval (hors navires de combat) / supplément SBYes
valeur de réponse réglable, réglage du courant (Ir) / du déclenchement L / avec caractéristique I2t
valeur de réponse en courant réglable / pour déclenchement G / avec caractéristique standard
Courant de réglage de la valeur de réponse ajustable (Ig) / pour déclenchement G / avec caractéristique I²t
type de sections transversales des conducteurs raccordables / pour raccordement par bornes plates / maximum50 x 28 mm
type de sections transversales des conducteurs connectables / pour connexion par bornes plates / minimum20 x 4 mm
Pertes de puissance [W] / pour la valeur nominale du courant / en courant alternatif / à chaud / par pôle50.33 W
Caractéristiques du produit / Pour conducteurs neutres / Évolutif / Rénovable / Protection contre les courts-circuits et les surchargesYes
Conception du commutateur de charge / selon UL 489 / Disjoncteur de chauffage, de climatisation et de réfrigération (type HACR)Yes
Approbation générale du produitConfirmationDiversEMCDéclaration de conformitéCertificats d'essaisMarine / Transport maritimeCertificats d'essais de type / Rapport d'essaiAutreMarchandises dangereusesConfirmationDiversDiversInformations de transportGeneral Product Approval

Description du produit

circuit breaker 3VA6 UL frame 800 breaking capacity class C 100kA @ 480 V 3-pole, line protection ETU860, LSIG, In=600A overload protection Ir=240A ... 600A short circuit protection. Manufactured to o
Caractéristiques principales
  • Qualité de niveau industriel
  • Conforme RoHS
  • Certifié CE
  • Garantie d’un an

Détails techniques

Confirmation

Documents du produit

Fiche technique

Spécifications techniques et données de performance

Manuel d'utilisateur

Guide d'installation et d'utilisation

Top