| Paramètre | Valeur |
|---|---|
| AWG | similar to AWG 22 |
| EAN | 4048879435673 |
| Formulaire | 40821 |
| Codage | M12, A-coded |
| Bouclier | no |
| eClass | 27279218 |
| Art. n° : | 7999-40821-2530060 |
| Matériel | PUR |
| Ø extérieur | 4.3 mm ±5% |
| normes | DIN EN 61076-2-101 (M12), DIN EN 61076-2-104 (M8) |
| Type de câble | 5 (PUR schweißfunkenbeständig) |
| Protection | IP67 inserted and tightened (EN 60529) |
| écran LED | no |
| Couleur de la veste | gray |
| Nombre de poteaux | M12, 4-pole – M8, 3-pole |
| Tension d'essai | 2 500 V AC |
| vitesse de torsion | 35 cycles/min |
| Couleur (veste) | gray |
| Groupe de matériaux | IEC 60664-1, category I |
| unité d'emballage | 1 |
| contrainte de torsion | ±360°/m |
| Isolation des fils | PP (br, bl, bk) |
| Diamètre (noyau) | 3 × 0.34 mm² |
| Matériau (fil) | Cu wire, bare |
| Méthode de montage | inserted, tightened |
| Tension nominale | 300 V AC |
| Résistance (noyau) | max. 60 Ω/km (20 °C) |
| Approbation (câble) | cRUus (AWM-Style 20549/10493); CE conform |
| Matériau de verrouillage | Zinc die casting, matte nickel plated |
| Verrouillage des ports | Screw thread M8/M12 × 1 mm (recommended torque 0.4/0.6 Nm) self-securing |
| Degré de pollution | 3 |
| glande de compression | M8 (SW9), M12 (SW13) |
| Matériau (joint) | FKM |
| Matière (veste) | PUR (UL/CSA), welding spark |
| Tension de fonctionnement | max. 60 V AC/DC |
| Extérieur-Ø (veste) | 4.3 mm ±5% |
| Plage de température | -25...+85 °C, depending on cable quality |
| pays d'origine | DE |
| Propriétés de la piste C | 10 Mio. |
| Poids du câble [g/m] | 29,70 |
| Matériel (contact) | Copper alloy |
| résistance thermique | flame retardant UL, FT2, IEC 60332-1, IEC 60332-2-2, welding spark resistant |
| Rayon de courbure (fixe) | 5 × outer Ø |
| Construction (noyau) | 42 × 0.1 mm (multi-strand wire class 6) |
| Tension de surtension nominale | 1.5 kV |
| résistance chimique | good resistance to oil, gasoline and chemicals (EN 60811-404) |
| Produit alternatif : | Product ComparisonY connectorMale straight – females straightM12, 4-pole – M8, 3-poleM12, A-codedArt-No. 7005 - M12/M8 Lite - (plastic hexagonal screw) on requestPlastic housings with good resistance against chemicals and oils. The resistance to aggressive media should be individually tested for your application. Further details on request. Further cable lengths on request.FormForm40821CablesNo./diameter of wires3 × 0.34 mm²Wire isolationPP (br, bl, bk)C-track properties10 Mio.Material (jacket)PUR (UL/CSA), welding sparkOuter Ø4.3 mm ±5%Bend radius (moving)10 × outer ØTemperature range (fixed)-40...+80 °CTemperature range (mobile)-25...+80 °CCable identification253Cable Type5 (PUR schweißfunkenbeständig)Approval (cable)cRUus (AWM-Style 20549/10493); CE conformCable weight [g/m]29,70Material (wire)Cu wire, bareResistor (core)max. 60 Ω/km (20 °C)Single wire Ø (core)0.1 mmConstruction (core)42 × 0.1 mm (multi-strand wire class 6)Diameter (core)3 × 0.34 mm²AWGsimilar to AWG 22Material (wire isolation)PPMaterial property (wire isolation)CFC-, halogen-, cadmium-, silicone- and lead-freeShore hardness (wire isolation)74 ±3 DWire-Ø incl. isolation1.25 mm ±5%Color/numbering of wiresbr, bk, blStranding combination3 wires twistedShieldnoMaterial (jacket)PURMaterial property (jacket)CFC-, halogen-, cadmium-, silicone- and lead-free, matt, low-adhesion, machine easy to process, abrasion-resistant, hydrolysis-, microbial- and welding spark resistantShore hardness (jacket)58 ±3 DOuter-Ø (jacket)4.3 mm ±5%Color (jacket)graychemical resistancegood resistance to oil, gasoline and chemicals (EN 60811-404)thermal resistanceflame retardant UL, FT2, IEC 60332-1, IEC 60332-2-2, welding spark resistantNominal voltage300 V ACTest voltage2 500 V ACCurrent load capacityto DIN VDE 0298-4Temperature range (fixed)-40...+80 °C, (+90 °C at max. 10 000 operating hours)Temperature range (mobile)-25...+80 °C, (+90 °C at max. 10 000 operating hours)Bend radius (fixed)5 × outer ØBend radius (moving)10 × outer ØNo. of bending cycles (C-track)max. 10 Mio. (25 °C)Traversing distance (C-track)max. 5 m (horizontal)Travel speed (C-track)max. 3.3 m/sAcceleration (C-track)max. 5 m/s²Torsion stress±360°/mNo. of torsion cyclesmax. 1 Mio. (25 °C)Torsion speed35 cycles/minJacket ColorgrayTechnical DataOperating voltagemax. 60 V AC/DCRated surge voltage1.5 kVOperating current per contactmax. 4 ANo. of polesM12, 4-pole – M8, 3-poleMaterial groupIEC 60664-1, category ICodingM12, A-codedLED displaynoLocking of portsScrew thread M8/M12 × 1 mm (recommended torque 0.4/0.6 Nm) self-securingCompression glandM8 (SW9), M12 (SW13)ProtectionIP67 inserted and tightened (EN 60529)MaterialPURLocking materialZinc die casting, matte nickel platedsuitable for corrugated tube (internal Ø)6.5 mmGeneral dataStandardsDIN EN 61076-2-101 (M12), DIN EN 61076-2-104 (M8)Mounting methodinserted, tightenedMaterial (contact)Copper alloyMaterial (contact surface)AuMaterial (gasket)FKMPollution Degree3Temperature range-25...+85 °C, depending on cable qualityCommercial datacountry of originDEcustoms tariff number85444290EAN4048879435673eClass27279218Packaging unit1 |
| Rayon de courbure (en mouvement) | 10 × outer Ø |
| Identification des câbles | 253 |
| capacité de charge actuelle | to DIN VDE 0298-4 |
| Nombre de cycles de torsion | max. 1 Mio. (25 °C) |
| Nombre/diamètre des fils | 3 × 0.34 mm² |
| Fil unique Ø (âme) | 0.1 mm |
| Combinaison d'échouage | 3 wires twisted |
| numéro de tarif douanier | 85444290 |
| Accélération (voie C) | max. 5 m/s² |
| Vitesse de déplacement (voie C) | max. 3.3 m/s |
| Dureté Shore (veste) | 58 ±3 D |
| Fil-Ø avec isolation | 1.25 mm ±5% |
| Couleur/numérotation des fils | br, bk, bl |
| Matériau (isolation des fils) | PP |
| Plage de température (fixe) | -40...+80 °C |
| Matériau (surface de contact) | Au |
| Propriétés matérielles (veste) | CFC-, halogen-, cadmium-, silicone- and lead-free, matt, low-adhesion, machine easy to process, abrasion-resistant, hydrolysis-, microbial- and welding spark resistant |
| Plage de température (mobile) | -25...+80 °C |
| Courant de fonctionnement par contact | max. 4 A |
| Distance parcourue (voie C) | max. 5 m (horizontal) |
| Nombre de cycles de flexion (voie C) | max. 10 Mio. (25 °C) |
| dureté Shore (isolation des fils) | 74 ±3 D |
| Propriétés des matériaux (isolation des fils) | CFC-, halogen-, cadmium-, silicone- and lead-free |
| convient aux tubes ondulés (Ø intérieur) | 6.5 mm |
Spécifications techniques et données de performance
Guide d'installation et d'utilisation