| Paramètre | Valeur |
|---|---|
| When connecting the conductor, make sure that the CAPAROC modules are not pulled apart due to tensile force. Gaps must not be created between the modules. | |
| Fusible | electronic |
| Note | LABS release – in accordance with test specification VW PV 3.10.7:2005-0 |
| Profondeur | 111.3 mm (incl. DIN rail 7.5 mm) |
| Largeur | 12.4 mm |
| Hauteur | 132.4 mm |
| Altitude | ≤ 4000 m (amsl) |
| Matériel | PA 6 |
| Efficacité | > 99 % |
| Type de produit | Device circuit breakers |
| chute de tension | 0.06 V (at 4 A) |
| Test d'humidité | 96 h, 95 % RH, 40 °C |
| Type de montage | pluggable onto CAPAROC CR… current rail |
| Tension nominale | 12 V DC |
| Heure d'arrêt | 5 s (with overload 1.1…1.3 x INat IN≥ 4 A) |
| Identification | UL/C-UL Listed UL 508 |
| Famille de produits | CAPAROC |
| LED du canal éteinte | off (Channel switched off) |
| LED rouge du canal | lit (Channel switched off, over- or undervoltage active) |
| Nombre de canaux | 2 |
| Nombre d'emplacements | 2 |
| Délai d'allumage | 50 ms (each channel preset by default) |
| Méthode de déclenchement | E (electronic) |
| Degré de pollution | 2 |
| Classe de protection | III |
| Courant nominal IN | 4 A DC (per channel) |
| longueur de dénudage | 10 mm |
| LED verte du canal | lit (Channel switched on) |
| Méthode de connexion | Push-in connection |
| Section transversale AWG | (converted acc. to IEC) |
| Élément de sécurité | 5 A DC (per output channel) |
| Tension de fonctionnement | 10 V DC ... 30 V DC |
| dissipation de puissance | typ. 0.6 W (no load at 24 V) |
| Choc (opération) | 30g (11 ms period, half-sine shock pulse, according to IEC 60068-2-27) |
| LED jaune du canal | lit (Channel switched on, channel load > 80% ) |
| rigidité diélectrique | 35 V DC (Load circuit) |
| Dessin coté | |
| Résistance à la rétroaction | max. 35 V DC |
| Nombre de positions | 1 |
| Tension de surtension nominale | 0.5 kV |
| Degré de protection | IP20 |
| Charge capacitive maximale | ≤ 60000 µF (Depending on the current setting and the short-circuit current available) |
| Fusible de secours requis | Only required if Imaxof the power supply > the short-circuit switching capacity. Integrated failsafe element. |
| LED rouge-verte du canal | flashing (Channel switched off, programming mode active, current adjustment after overload or short-circuit release) |
| Mesure de la tolérance I | ± 10 % (typ.) |
| Vibration (fonctionnement) | 5g (10 ... 150 Hz / 10 cycles / axis / X, Y, Z) |
| LED rouge-jaune du canal | flashing (Channel is overloaded and is switched off) |
| Coupure de surtension | ≥ 32.5 V DC (active) |
| Coupure en cas de sous-tension | ≤ 8.5 V DC (active) |
| Normes/spécifications | EN 61000-6-2 |
| Limitation du courant actif | typ. 2.0 x INat IN≤ 3 A |
| Courant en circuit fermé I0 | typ. 25 mA (no load at 24 V) |
| MTBF (IEC 61709, SN 29500) | 11364927 h (at 25 °C with 21 % load) |
| Section transversale du conducteur AWG | 24 ... 12 |
| Courant nominal (préréglé) | 1 A |
| Section transversale du conducteur rigide | 0.2 mm² ... 4 mm² |
| Température ambiante (fonctionnement) | -30 °C ... 65 °C (The temperature range of the power module must be taken into consideration) |
| Section transversale du conducteur flexible | 0.2 mm² ... 4 mm² |
| Capacité de commutation en court-circuit | 300 A |
| Indice d'inflammabilité selon la norme UL 94 | V-0 |
| Température ambiante (stockage/transport) | -40 °C ... 70 °C |
| Section transversale du conducteur, flexible, avec embout, avec gaine plastique | 0.25 mm² ... 4 mm² |
| Section transversale du conducteur flexible, avec virole sans gaine plastique | 0.25 mm² ... 4 mm² |
Spécifications techniques et données de performance
Guide d'installation et d'utilisation