| Paramètre | Valeur |
|---|---|
| Article | Specifications |
| Poids | 1.2 kg approx. |
| Détails | Wide-area fan type |
| Produit | Wide-area Ionizer |
| Matériel | Bar unit enclosure: ABS, Fan unit enclosure: ABS, Discharge needles: Tungsten, Mounting bracket: SPCC |
| Accessoires | AC adapter (Note), F.G. connection cable: 1 pc., Spare replacement filters: 5 pcs., Three-pronged outlet with ground pin: 1 pc., Blindfold seals: 2 sheets(Note:Please prepare an AC cable separately as it is needed.The following cables are available as optionals: CN-ACCN-C2: AC cable (conforming to CCC), CN-ACKR-C2: AC cable (conforming to KTL)) |
| Équilibre ionique | plus or minus10 V or less(Note:Typical value at a distance of 300 mm 11.811 in from the front surface of the air outlet at the unit center at maximum fan speed.) |
| Numéro de pièce | ER-TF06-EX |
| Nom du produit | Wide-area Ionizer ER-TF(Discontinued) |
| Numéro de produit | ER-TF06-EX |
| Tension d'alimentation | Accessory AC adapter input: 100 to 240 V AC plus or minus10 % 50/60 Hz(Output: 24 V DC) |
| Humidité ambiante | 35 to 65 % RH (No dew condensation) |
| Méthode de décharge | Steady-state DC |
| génération d'ozone | 0.02 ppm or less(Note: Typical value at a distance of 300 mm 11.811 in from the front surface of the air outlet at the unit center at maximum fan speed.) |
| Consommation d'énergie | 80 VA or less (at 100 V: 70 VA or less) |
| Température ambiante | 0 to + 50 ℃+ 32 to + 122℉(No dew condensation),AC adapter: 0 to + 40 ℃+ 32 to + 104℉ |
| délai de retrait des frais | 1 sec. approx. (±1,000 V → ±100 V)(Note: Typical value at a distance of 200 mm 7.874 in from the front surface of the air outlet at the unit center at maximum fan speed.) |
| Sortie d'erreur (ERREUR) | NPN open-collector transistor• Maximum sink current: 50 mA• Applied voltage: 30 V DC or less (between output and 0 V)• Residual voltage: 1 V or less (at 50 mA sink current) |
| Indicateurs : Barre : COCHER | Orange LED (Lights up when discharge part check or fan check is detected) |
| Indicateurs : Barre : ERREUR | Red LED (Lights up when discharge part error or fan error is detected) |
| Indicateurs : Barre : PUISSANCE | Green LED (Lights up when power supplied) |
| Tension de sortie de décharge | plus or minus6,000 V approx. |
| Indicateurs : Ventilateur : État du ventilateur | Yellow LED (Lights up when fan error or fan check is detected) |
| Sortie d'erreur : Opération de sortie | OFF if abnormal discharge, object inserted into discharge window or fan problem detected; normally ON |
| Directives conformes au marquage CE | EMC Directive, RoHS Directive |
| Indicateurs : Ventilateur : État de la partie refoulement | Yellow LED (Lights up when discharge part error or discharge part check is detected) |
| Sortie d'erreur : Protection contre les courts-circuits | Incorporated |
Spécifications techniques et données de performance