| Paramètre | Valeur |
|---|---|
| Article | Specifications |
| Câble | 0.15 mm24-core (emitter of a thru-beam type: 2-core) cabtyre cable, 2 m6.562 ftlong |
| Sortir | NPN open-collector transistor- Maximum sink current: 50 mA- Applied voltage: 26.4 V DC or less (between output and 0 V)- Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) |
| Détails | Thru-beam type |
| Produit | Amplifier Built-in Ultra-compact Laser Sensor |
| Matériel | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate |
| Accessoire | MS-EXL2-2 (Mounting plate): 2 pcs. |
| Protection | IP67 (IEC) |
| Numéro de pièce | EX-L212-C5 |
| Nom du produit | Amplifier Built-in Ultra-compact Laser Sensor EX-L200 |
| Répétabilité | Perpendicular to sensing axis: 0.05 mm0.0020 inor less |
| temps de réponse | 0.5 ms or less |
| Portée de détection | 3 m9.843 ft |
| Numéro de produit | EX-L212-C5 |
| Objet de détection | Opaque object of ø3 mmø0.118 inor more |
| Tension d'alimentation | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Indicateur de puissance | - |
| Humidité ambiante | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Élément émetteur | Red semiconductor laser Class 1 (IEC / JIS/ FDA) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration)(Maximum output: 390 μW, Peak emission wavelength: 655 nm0.026 mil) |
| résistance aux chocs | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Éclairage ambiant | Incandescent light: 3,000 lx or less at the light-receiving face |
| Température ambiante | -10 to +55 ℃+14 to +131 ℉(No dew condensation or no icing condition),Storage: -30 to +70 ℃-22 to +158 ℉ |
| Consommation de courant | Emitter: 10 mA or lessReceiver: 10 mA or less |
| Indicateur de fonctionnement | Orange LED (lights up when the output is ON) (incorporated on the receiver for thru-beam type) |
| Indicateur de stabilité | Green LED (lights up under stable light received condition or stable dark condition) (incorporated on the receiver for thru-beam type) |
| Réglage de la sensibilité | - |
| résistance aux vibrations | 10 to 500 Hz frequency, 1.5 mm0.059 indouble amplitude (10 G max.) in X, Y and Z directions for two hours each |
| résistance d'isolation | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Sortie : Opération de sortie | Light-ON / Dark-ON selectable by the output operation switching input |
| tenue en tension | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Taille du point d'émission (typique) | Approx. 8 × 5.5 mm0.315 × 0.217 in(vertical × horizontal)(at a sensing distance of 1 m)(Note) In the case sensing distance is 3 m9.843 ft, the emission spot size is H 17 × W 11 mmH 0.669 × W 0.433 in(visual reference value). |
| Conformité à la directive de marquage CE | EMC Directive, RoHS Directive |
| Sortie : Protection contre les courts-circuits | Incorporated (short-circuit protection / inverse polarity protection) |
| Objet de détection minimal (typique) | - |
| Répétabilité (typique) (perpendiculaire à l'axe de détection) | - |
Spécifications techniques et données de performance