| Paramètre | Valeur |
|---|---|
| Couleur | red (RAL 3001) |
| Profondeur | 29.6 mm |
| Pas | 8.2 mm |
| Largeur | 72.1 mm |
| Hauteur | 29.6 mm |
| Matériel | Copper |
| Type de produit | Jumper |
| Type de montage | Plug-in mounting |
| Révision de l'article | 01 |
| Matériau isolant | PA |
| Note sur l'application | Version with single- or double-sided cutting edge. Keep in mind the possible impact on touch protection as well as the air clearances and creepage distances. For applications in explosion-proof areas, the voltage reduces to the voltage specified in the Ex certificate for bridges that are cut to length. |
| Nombre de positions | 9 |
| courant de charge maximal | 41 A (The current values for the jumpers can deviate when used in different modular terminal blocks. The precise values can be found in the accessories data for the respective modular terminal blocks.) |
| Température ambiante (assemblage) | -5 °C ... 70 °C |
| Température ambiante (actionnement) | -5 °C ... 70 °C |
| Température ambiante (fonctionnement) | -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) |
| Humidité admissible (fonctionnement) | 20 % ... 90 % |
| Indice d'inflammabilité selon la norme UL 94 | V0 |
| Température ambiante (stockage/transport) | -25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C) |
| Humidité admissible (stockage/transport) | 30 % ... 70 % |
Spécifications techniques et données de performance
Guide d'installation et d'utilisation