Heures de service : Lundi à vendredi 9h00-18h00
FGQDB3H/6 - FGQDB3H/6 431163 GENERAL ELECTRIC FG-RCD DiffBottom-3p 400-690V
En stock Produit phare

FGQDB3H/6

FGQDB3H/6 431163 GENERAL ELECTRIC FG-RCD DiffBottom-3p 400-690V

$0.00USD
4734 en stock
Spécifications clés
Statut:Active
ETIM 5.0 (DIMENSIONS):EC001021
ETIM 6.0 (DIMENSIONS):EC001021
Poids (SPÉCIFICATIONS):5 kg
Informations sur le fournisseur
Produits : 0
Habituellement expédié sous 2 à 3 jours ouvrables
Qualité garantie
Livraison rapide
Support technique

Spécifications techniques

ParamètreValeur
StatutActive
ETIM 5.0 (DIMENSIONS)EC001021
ETIM 6.0 (DIMENSIONS)EC001021
Poids (SPÉCIFICATIONS)5 kg
Plage (STATUT DE LA COMMANDE/LIVRAISON)Protection
Série (STATUT DE COMMANDE/LIVRAISON)Residual Current devices
Type de cadre (STATUT DE LA COMMANDE/LIVRAISON)G frame (400A/630A)
Mesures (STATUT DE LA COMMANDE/LIVRAISON)109x138.7x125.4 mm
Nombre de poteaux (STATUT DE LA COMMANDE/LIVRAISON)3P
Détail de l'accessoire (STATUT DE LA COMMANDE/LIVRAISON)Differential bottom
Emballage standard (STATUT DE LA COMMANDE/LIVRAISON)1

Description du produit

More details
Caractéristiques principales
  • Qualité de niveau industriel
  • Conforme RoHS
  • Certifié CE
  • Garantie d’un an

Détails techniques

A record plus circuit breaker can offer protection against earth leakage currents by using an add-on residual current device (RCD). A line of three pole completely integrated add-on devices are available as side mounted models (FD frame size) or as units that are fitted below the trip unit of the breaker (FD, FE and FG frame sizes). In all cases the RCD unit interfaces directly with the circuit breaker without the use of any secondary wiring connections. Earth RCD has a sensor placed around the phase and neutral current paths that detects the vectorial sum of the phase and neutral currents. When this sum is no longer zero it is assumed that current is flowing to earth (residual current). If this value exceeds the threshold set on the RCD the breaker connected to the device is tripped.The RCD units electrical power is supplied by the line voltage of the breaker it is linked to. By use of a multi-phase bridge the design still works when one phase and the neutral is present. A pouch on the RCD allows one to place one BAT contact NO or NC which allows a remote signal on earth faults. A Record Plus breaker and an RCD combination can be connected like any stand-alone breaker and are available as fixed or plug-in devices. The mains connection interface of the RCD is an exact replica of the breaker connection area, thus allowing the use of all standard breaker terminals.

Documents du produit

Fiche technique

Spécifications techniques et données de performance

Manuel d'utilisateur

Guide d'installation et d'utilisation

Top