| Paramètre | Valeur |
|---|---|
| 2000 m (With UL approval) | |
| ATEX | Ex II 3 G Ex nA IIC T4 Gc X (Please follow the special installation instructions in the documentation!) |
| MTBF | 479 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
| MTTF | 1400 Years (SN 29500 standard, temperature 25°C, operating cycle 21 % (5 days a week, 8 hours a day)) |
| Couleur | green |
| Profondeur | 114.5 mm |
| Largeur | 22.5 mm |
| Hauteur | 99 mm |
| Latence | ± 1.3 µs (Store&Forward mode, 10/100 Mbps, depending on the frame size) |
| Altitude | 5000 m (For restrictions see manufacturer's declaration) |
| Poids net | 179 g |
| Longueur d'onde | 1300 nm |
| Conformité | CE-compliant |
| Interface 1 | Ethernet interface, 10/100BASE-T(X) in acc. with IEEE 802.3u |
| LED de signalisation | Activity, link status, 10/100 Mbps |
| Lien via | Link fault pass through |
| Fonctions de base | Store-and-forward media converter |
| Matériau du boîtier | PA 6.6-FR |
| UL, États-Unis / Canada | cULus listed UL 508 |
| Méthode de connexion | Plug-in screw terminal block (COMBICON), redundancy possible |
| Récepteur à portée étendue | -14 dBm (dynamic in link mode (average)) |
| circuit de protection | Protection against polarity reversal |
| longueur de transmission | 100 m (twisted pair, shielded) |
| milieu de transmission | Copper |
| Degré de protection | IP20 |
| Isolation électrique | according to IEEE 802.3 |
| Plage de tension d'alimentation | 18 V DC ... 30 V DC (Screw connection) |
| Basculement MDI-/MDI-X | Auto-MDI(X) |
| Normes/réglementations | EN 60950-1 |
| Modes d'auto-négociation | Auto |
| Capacité de transmission maximale | ≤ -14 dBm ((50/125 µm) dynamic in link mode (average)) |
| Capacité de transmission minimale | ≥ -23.5 dBm ((50/125 µm) dynamic in link mode (average)) |
| Consommation de courant typique | < 100 mA (24 V DC) |
| Sensibilité minimale du récepteur | -31 dBm (dynamic in link mode (average)) |
| Compatibilité électromagnétique | Conformance with EMC Directive 2004/108/EC (valid until 19.04.2016) / 2014/30/EU (valid from 20.04.2016) |
| Température ambiante (fonctionnement) | -40 °C ... 65 °C |
| Conductor cross section AWG max. | 14 |
| Conductor cross section AWG min. | 24 |
| Humidité admissible (fonctionnement) | 30 % ... 95 % (non-condensing) |
| Conductor cross section solid max. | 2.50 mm² |
| Conductor cross section solid min. | 0.20 mm² |
| Conductor cross section flexible max. | 2.50 mm² |
| Conductor cross section flexible min. | 0.20 mm² |
| Température ambiante (stockage/transport) | -40 °C ... 85 °C |
| Humidité admissible (stockage/transport) | 30 % ... 95 % (non-condensing) |
| Interface de données de tension de test/alimentation | 1.5 kVrms(50 Hz, 1 min.) |
| Section maximale du conducteur AWG, flexible | 14 |
| Section minimale du conducteur AWG, flexible | 24 |
| Longueur de transmission incluant une réserve système de 3 dB | 6.4 km (with F-G 50/125 0,7 dB/km F 1000) |
Spécifications techniques et données de performance