Heures de service : Lundi à vendredi 9h00-18h00
FM-215-8 - FM-215-8 PANASONIC flow sensor FM200, 100l/minø8,NPN
En stock Produit phare

FM-215-8

FM-215-8 PANASONIC flow sensor FM200, 100l/minø8,NPN

$0.00USD
3138 en stock
Spécifications clés
Article:Specifications
Poids:Net weight: 70 g approx., Gross weight: 135 g approx.
Détails:Resin body type
Afficher:4 digits + 4 digits 2-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
Informations sur le fournisseur
PANASONIC
PANASONIC
Produits : 4316
Habituellement expédié sous 2 à 3 jours ouvrables
Qualité garantie
Livraison rapide
Support technique

Spécifications techniques

ParamètreValeur
ArticleSpecifications
PoidsNet weight: 70 g approx., Gross weight: 135 g approx.
DétailsResin body type
Afficher4 digits + 4 digits 2-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
ProduitIntegrated Display Type Digital Flow Sensor
MatérielEnclosure: ABS, Body: Polyamide (Aluminum body type: Aluminum), Switch: EPDM, Display: Acrylic, Mounting screw part (Resin body type): Brass Current plate / Port filter: Stainless steel (used for the gas contact area), Sensor chip: Silicon, Gasket: Fluorine rubber
LinéaritéWithin ±3 % F.S. (Ambient temperature +25 ℃ +77 ℉, flow rate range 3 to 100 % F.S., atmospheric criteria on secondary side)
Taille du portø8 ø0.315 push-in
ProtectionIP40 (IEC)
AccessoiresCN-F15-C1 (Connector attached cable 1 m 3.281 ft): 1 pc.
Numéro de pièceFM-215-8
longueur du câbleTotal length up to 10 m 32.808 ft is possible with 0.3 mm2, or more, cable.
Nom du produitIntegrated Display Type Digital Flow Sensor FM-200
RépétabilitéWithin ±1 % F.S.
Entrée externeON voltage: 0 to +0.4 VOFF voltage: +5 V to +V, or openInput time: 80 ms or more
Numéro de produitFM-215-8
Tension d'alimentation12 to 24 V DC ± 10 % Ripple P-P10 % or less
Humidité ambiante35 to 90 % RH, Storage: 35 to 90 % RH
Fluide applicableClean air, compressed air, nitrogen gas(Note):The clean air complies with JIS B 8392-1.1.1 to 5.6.2, and the compressed air complies with JIS B 8392-1.1.1 to 1.6.2.
résistance aux chocs100 m/s2acceleration (10 G approx.) in X, Y and Z directions three times each
Méthode de connexionConnector
Production comparativeNPN open-collector transistor・Maximum sink current: 50 mA or less・Applied voltage: 26.4 V DC or less (between comparative output and 0 V)・Residual voltage: 2.4 V or less (at 50 mA sink current)
Mise à la terre du boîtierFloating(Note):As a varistor (clamping voltage: approx. 40 V) is connected to the aluminum body type, do not apply voltage higher than the rated voltage of the sensor.
Température ambiante0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉
Consommation de courantNormal mode: 60 mA or less, ECO mode: 40 mA or less
débit à pleine échelle100 ℓ/min.(Note):Converted to volumetric flow at +20 ℃ +68 ℉ and 1 atmospheric pressure (101 kPa).
Plage de pression nominale-0.09 to +0.7 MPa
résistance aux vibrations10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude or 49 m/s2max. acceleration, in X, Y and Z directions for two hours each
Sortie de tension analogiqueOutput voltage: 1 to 5 V, Output impedance: 1 kΩ approx.[Refer to "Analog voltage output" for more details.]
résistance d'isolation10 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure (Excluding the aluminum body type)
Plage d'assurance de précisionBi-direction : -100 to -3 % F.S., +3 to +100 % F.S.One-side direction : +3 to +100 % F.S.(Note):Take care that if fluid flows in the vicinity of zero-point which is out of the accuracy assurance range, the instant flow rate value may forcibly display "zero", or the integrated flow display value may not be counted up, or the integrated pulse output may not be outputted.
Caractéristiques de pressionWithin ±5 % F.S. (-0.09 to +0.7 MPa, +25 ℃ +77 ℉, atmospheric criteria on secondary side)
tenue en tension1,000 V AC for one min. between all supply terminals connected together and enclosure (Excluding the aluminum body type)
résistance à la pression1 MPa
Valeur intégrée spécifiée1 ℓ
caractéristiques de températureWithin ±0.2 % F.S./℃ (+25 ℃ +77 ℉ criteria, +15 to +35 ℃ +59 to +95 ℉ ambient temperature range)
Résultats comparatifs : hystérésisWindow comparator mode: 1 to 8 % F.S. approx. (variable) (Factory settings: approx. 1 % F.S.), Hysteresis mode: Variable (minimum 1 digit)
Conformité à la directive de marquage CEEMC Directive, RoHS Directive
Sortie comparative : modes de sortieOutput OFF mode, window comparator mode, hysteresis mode, integrated output mode, integrated pulse output mode
Débit instantané : Plage d'affichage-110 to +110 ℓ/min.(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.).
Résultat comparatif : Temps de réponse50 ms, 80 ms, 120 ms, 200 ms, 400 ms, 800 ms, 1,500 ms, selectable by key operation
Débit intégré : Plage d'affichage±999999.9 ℓ(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.).
Sortie comparative : Protection contre les courts-circuitsIncorporated
Débit instantané : Réglage et résolution d’affichage0.1 ℓ/min.
Débit intégré : Réglage et résolution d’affichage0.1 ℓ

Description du produit

More details
Caractéristiques principales
  • Qualité de niveau industriel
  • Conforme RoHS
  • Certifié CE
  • Garantie d’un an

Documents du produit

Fiche technique

Spécifications techniques et données de performance

Manuel d'utilisateur

Guide d'installation et d'utilisation

Top