| Paramètre | Valeur |
|---|---|
| Article | Specifications |
| Câble | 0.3 mm23-core oil resistant cabtyre cable, 1 m3.281 ftlong |
| Sortir | NPN open-collector transistor- Maximum sink current: 100 mA- Applied voltage: 30 V DC or less (between output and 0 V)- Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) |
| Poids | Net weight : 45 g approx. |
| Détails | GL-18H/18HL type |
| Produit | Compact & Low Price Inductive Proximity Sensor |
| Matériel | Enclosure: Polyarylate |
| Hystérèse | 15 % or less of operation distance (with standard sensing object) |
| Protection | IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.Please check the resistivity of the sensor against the cutting oil you are using beforehand.) |
| Accessoires | MS-GL18HL (Sensor mounting bracket): 1 set |
| Numéro de pièce | GL-18HL |
| Nom du produit | Compact & Low Price Inductive Proximity Sensor GL |
| Numéro de produit | GL-18HL |
| Tension d'alimentation | 10 to 30 V DC Ripple P-P 10 % or less |
| rallonge de câble | Extension up to total 100 m328.084 ftis possible with 0.3 mm2, or more, cable. |
| Humidité ambiante | 45 to 85 % RH, Storage: 45 to 85 % RH |
| résistance aux chocs | 1,000 m/s2acceleration (100 G approx.) in X, Y and Z directions three times each |
| Température ambiante | -25 to +70 ℃-13 to +158℉,Storage: -25 to +70 ℃-13 to +158℉ |
| Consommation de courant | 10 mA or less |
| Indicateur de fonctionnement | Red LED (lights up when the output is ON) |
| Portée de détection stable | 0 to 10 mm0 to 0.394 in(Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. |
| résistance aux vibrations | 10 to 55 Hz frequency, 1.5 mm0.059 indouble amplitude in X, Y and Z directions for two hours each |
| résistance d'isolation | 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Distance de fonctionnement maximale | 12 mm0.472 in± 10 %(Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. |
| Fréquence de réponse maximale | 500Hz |
| Sortie : Opération de sortie | Normally open |
| Objet de détection standard | Iron sheet 40 × 40 × t 1 mm1.575 × 1.575 × t 0.039 in |
| tenue en tension | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Résultat : Catégorie d'utilisation | DC-12 or DC-13 |
| Conformité à la directive de marquage CE | EMC Directive, RoHS Directive |
| Résistance environnementale : degré de pollution | 3 (Industrial environment) |
| Variation de la plage de détection : caractéristiques de tension | Within ±2% for ±10 % fluctuation of the supply voltage |
| Variation de la plage de détection : caractéristiques de température | Over ambient temperature range -25 to +70 ℃-13 to +158℉: within ±10 % of sensing range at +20 ℃+68℉ |
Spécifications techniques et données de performance