| Paramètre | Valeur |
|---|---|
| Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque. | |
| Taper | D7 |
| Tests | DIN VDE 0627/86 |
| Largeur | 21 mm |
| Hauteur | 34.8 mm |
| Longueur | 21 mm |
| Série | HC-HS |
| Général | for HC-D7 housing, axial connection 2.0 mm, Allen key |
| Application | Power |
| Type de produit | Contact insert with a fixed no. of positions |
| Note de l'assemblée | To ensure correct use, installation in housing with IP54 protection or better is required |
| Courant nominal | 40 A |
| Révision de l'article | 04 |
| Diamètre de contact | 4 mm |
| Matériel de contact | Copper alloy |
| Hexagonal socket | SW2,0 |
| Numérotation des contacts | 1 - 2 |
| Couple de serrage | 0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing) |
| Profil de connexion | 2+PE |
| Degré de pollution | 3 |
| Dessin coté | |
| Nombre de positions | 2 |
| Tension de surtension nominale | 6 kV |
| Catégorie de surtension | III |
| Technologie de connexion | Axial screw connection |
| Type de matériau de contact | turned |
| Nombre de contacts de puissance | 2 |
| Tension nominale (III/3) | 400 V |
| Section transversale du conducteur | 4 mm² ... 10 mm² (The cross section specification refers to the geometric cross section of the cable used) |
| Matériau porteur de contact | PC |
| matériau de surface de contact | Ag |
| Cycles d'insertion/retrait | ≥ 500 |
| Section de connexion AWG | 10 ... 8 |
| Température ambiante (fonctionnement) | -40 °C ... 125 °C (including heating up of contacts) |
| Connexion conforme aux normes | IEC / EN |
| Constructional and testing regulations | DIN VDE 0627/86 |
| Indice d'inflammabilité selon la norme UL 94 | V0 |
| Longueur de dénudage du fil individuel | 8 mm +1 mm |