| Paramètre | Valeur |
|---|---|
| GTIN | 4046356410229 |
| Note | Made to Order (non-returnable) |
| Clé de commande | 1586277 |
| page du catalogue | Page 507 (C-2-2017) |
| Unité d'emballage | 10 pc |
| Pays d'origine | DE (Germany) |
| numéro de tarif douanier | 85366990 |
| (Données commerciales clés) | The axial screw connection must be established using a 2 mm Allen key (for stranded conductors only) |
| quantité minimale de commande | 10 pc |
| Size (Key Commercial Data) | D7 |
| (Normes et réglementations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| (Electrical characteristics) | IEC 60352 |
| Rated current (Material data) | 40 A |
| Connection (Key Commercial Data) | Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque. |
| Tension de surtension nominale (Données sur les matériaux) | 6 kV |
| Poids par pièce (emballage exclu) | 23.410 g |
| Matériau de contact (conditions ambiantes) | Copper alloy |
| Tension nominale (III/3) (Données sur les matériaux) | 400 V |
| Normes et réglementations RoHS en Chine | Environmentally Friendly Use Period = 50 |
| REACH SVHC (Normes et réglementations) | Lead 7439-92-1 |
| Méthode de connexion (Données commerciales clés) | Axial screw connection |
| Contact numbering (Key Commercial Data) | 1 - 2 |
| Tightening torque (Key Commercial Data) | 1.8 Nm |
| Température ambiante (fonctionnement) (Général) | -40 °C ... 125 °C (including heating up of contacts) |
| Degree of pollution (Key Commercial Data) | 3 |
| Nombre de postes (Données commerciales clés) | 2+PE |
| Overvoltage category (Key Commercial Data) | III |
| Assembly instructions (Key Commercial Data) | To ensure correct use, installation in housing with IP54 protection or better is required |
| Conductor cross section (Key Commercial Data) | 4 mm² ... 10 mm² |
| Matériau support de contact (conditions ambiantes) | PC |
| Matériau de la surface de contact (conditions ambiantes) | Ag |
| Insertion/withdrawal cycles (Key Commercial Data) | ≥ 500 |
| Connection cross section AWG (Key Commercial Data) | 10 ... 8 |
| Connection in acc. with standard (Electrical characteristics) | CUL |
| Longueur de dénudage du fil individuel (Données commerciales clés) | 8 mm +1 |
| Constructional and testing regulations (Electrical characteristics) | DIN VDE 0627/86 |
| Flammability rating according to UL 94 (Electrical characteristics) | V0 |