Spécifications clés
:Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
Taper:B16
Largeur:34 mm
Hauteur:47 mm
Informations sur le fournisseur
Produits : 0
Habituellement expédié sous 2 à 3 jours ouvrables
Qualité garantie
Livraison rapide
Support technique

Spécifications techniques

ParamètreValeur
Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
TaperB16
Largeur34 mm
Hauteur47 mm
Longueur84.1 mm
SérieHC-K
GénéralFor HEAVYCON ADVANCE and HEAVYCON housing of type B16/B32, axial connection for 2 mm Allen wrench
ApplicationPower/signal
Type de produitContact insert with a fixed no. of positions
Note de l'assembléeTo ensure correct use, installation in housing with IP54 protection or better is required
Courant nominal40 A (power contacts)
Révision de l'article04
Diamètre de contact4 mm
Matériel de contactCu alloy
Numérotation des contacts1 - 6 (power contacts)
Screwdriver blade0.5 x 3.5 mm (control contacts)
Couple de serrage2 Nm ... 2.5 Nm (PE connection)
Profil de connexion6+12+PE
Degré de pollution3
Dessin coté
Nombre de positions18
Tension de surtension nominale8 kV (power contacts)
Catégorie de surtensionIII
Technologie de connexionAxial screw connection (power contacts)
Type de matériau de contactturned
Nombre de contacts de puissance6
Tension nominale (III/3)690 V
Section transversale du conducteur2.5 mm² ... 10 mm² (power contacts)
Nombre de contacts de commande12
Matériau porteur de contactPC
Cycles d'insertion/retrait≥ 500
Section de connexion AWG12 ... 8 (power contacts)
Température ambiante (fonctionnement)-40 °C ... 125 °C
Drill hole distance, horizontal77.5 mm
Tension nominale des contacts de puissance230/400 V
Indice d'inflammabilité selon la norme UL 94V0
Longueur de dénudage du fil individuel8 mm +1 mm (Power 6 mm² ... 10 mm²)
Matériau de la surface de contact, contact électriqueAg
Matériau de la surface de contact, contact de contrôleAg

Description du produit

Contact insert, number of poles: 6+12+PE, size: B16, power contacts: 6, control contacts: 12, Female, Axial screw connection, 690 V, 40 A, 2.5 mm² ... 10 mm², application: Power/signal