| Paramètre | Valeur |
|---|---|
| GTIN | 4046356308236 |
| Note | Made to Order (non-returnable) |
| Clé de commande | 1585731 |
| page du catalogue | Page 553 (C-4-2015) |
| Unité d'emballage | 2 pc |
| Pays d'origine | DE (Germany) |
| numéro de tarif douanier | 85366990 |
| (Conditions ambiantes) | 5 Nm (22 mm²) |
| quantité minimale de commande | 100 pc |
| Matériel de contact (Général) | Copper alloy |
| Rated current (Dimensions) | 70 A |
| Largeur (Données commerciales clés) | 34.2 mm |
| Taille (Données commerciales clés) | 46.5 mm |
| Longueur (Données commerciales clés) | 14.6 mm |
| Connection profile (Dimensions) | 2 |
| Rated surge voltage (Dimensions) | 8 kV |
| Matériau support de contact (Général) | PC |
| Matériau de la surface de contact (Généralités) | Ag |
| Rated voltage (III/3) (Dimensions) | 1000 V |
| Series (Mechanical characteristics) | HC-M-02 |
| Poids par pièce (emballage exclu) | 30.900 g |
| Hexagonal socket (Ambient conditions) | SW2,5 |
| Couple de serrage (conditions ambiantes) | 4 Nm (for 14 mm² ... 16 mm²) |
| Connection (Mechanical characteristics) | Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque. |
| Minimum housing height (Ambient conditions) | 72 mm |
| Section transversale du conducteur (conditions ambiantes) | 14 mm² ... 22 mm² |
| Connection method (Mechanical characteristics) | Axial screw connection |
| Connection in acc. with standard (Material data) | UL |
| Degré de pollution (Caractéristiques mécaniques) | 3 |
| Cycles d'insertion/retrait (conditions ambiantes) | ≥ 500 |
| Connection cross section AWG (Ambient conditions) | 6 ... 4 |
| Catégorie de surtension (Caractéristiques mécaniques) | III |
| Assembly instructions (Mechanical characteristics) | Use 2.5 mm Allen wrenches for axial connection. Only for stranded wires. For housing heights h ≥ 52 mm. Plug-in connections may only be operated only when there is no load/voltage. |
| Number of module slots (Mechanical characteristics) | 1 |
| Indice d'inflammabilité selon la norme UL 94 (Données sur les matériaux) | V0 |
| Diamètre du fil, isolation comprise (conditions ambiantes) | 10 mm |
| Ambient temperature (operation) (Electrical characteristics) | -40 °C ... 125 °C |
| Stripping length of the individual wire (Ambient conditions) | 11 mm +1 (14 mm² ... 16 mm²) |
| Indice d'inflammabilité selon la norme UL 94 (Caractéristiques mécaniques) | V0 |