| Paramètre | Valeur |
|---|---|
| Note regarding axial connection technology:Only for stranded wires. The conductor cross sections stated refer to the geometric cross section of the cable used.Use of cables with a geometric cross section very different from that of the cable's nominal cross section should be checked before use.The wiring space of the axial screw method is designed for fine strand cables according to VDE 0295 class 5. Deviating cable structures (e.g. class 6 cables) should be checked before use.ConnectionBefore starting to connect, ensure that the tapered screw is turned back all the way (chamber is open). The cables must not be twisted. The cores should be slid to the limit stop in the contact chamber (until insulation touches contact). Hold cores in position and use socket wrench to tighten. The used core end should be cut off before connecting again. The connection screw may only be retightened once to prevent the strands from breaking. To prevent damage to the contact, the core / cable should be mechanically intercepted at an appropriate distance from the connection point (e.g. by using a plate cutout). DIN VDE 0100-520:2003-06 contains information on how to do this correctly. | |
| Largeur | 34.2 mm |
| Hauteur | 41.8 mm |
| Longueur | 14.6 mm |
| Série | HC-M-02 |
| Général | For HEAVYCON housing type B6 to B48, HC-M-MHR... hinged retaining frame required |
| Application | Power |
| Type de produit | Modular contact insert |
| Note de l'assemblée | - Connection of the wires using a 2 mm Allen wrench.- Housing height ≥ 52 mm.- Axial screw connection only for flexible wires.- Plug-in connections may only be operated only when there is no load/voltage. |
| Courant nominal | 40 A |
| Matériel de contact | Copper alloy |
| Hexagonal socket | SW 2 |
| Numérotation des contacts | 1 - 2 |
| Couple de serrage | 1.5 Nm (2.5 mm² ... 4 mm²) |
| Profil de connexion | 2 |
| Degré de pollution | 3 |
| Dessin coté | |
| Nombre de positions | 2 |
| Tension de surtension nominale | 8 kV |
| Catégorie de surtension | III |
| Technologie de connexion | Axial screw connection |
| Tension nominale (III/3) | 1000 V |
| Nombre d'emplacements pour modules | 1 |
| Section transversale du conducteur | 2.5 mm² ... 8 mm² (The cross section specification refers to the geometric cross section of the cable used) |
| Matériau porteur de contact | PC |
| matériau de surface de contact | Ag |
| Cycles d'insertion/retrait | ≥ 500 |
| Section de connexion AWG | 12 ... 10 |
| Température ambiante (fonctionnement) | -40 °C ... 125 °C |
| Connexion conforme aux normes | IEC / EN |
| Indice d'inflammabilité selon la norme UL 94 | V0 |
| Longueur de dénudage du fil individuel | 8 mm +1 mm (for 6 mm²) |