| Paramètre | Valeur |
|---|---|
| GTIN | 4055626025087 |
| Clé de commande | 1414365 |
| page du catalogue | Page 565 (C-2-2017) |
| Unité d'emballage | 5 pc |
| (Dimensions) | 8 kV (control contacts) |
| Pays d'origine | PL (Poland) |
| numéro de tarif douanier | 85389099 |
| (Conditions ambiantes) | 8 mm (6 mm (2,5 mm²)) |
| quantité minimale de commande | 5 pc |
| Matériel de contact (Général) | Copper alloy |
| Rated current (Dimensions) | 40 A (power contacts) |
| Largeur (Données commerciales clés) | 34.2 mm |
| (Normes et réglementations) | No hazardous substances above threshold values |
| Taille (Données commerciales clés) | 39.1 mm |
| Longueur (Données commerciales clés) | 14.6 mm |
| (Caractéristiques mécaniques) | Crimp connection (control contacts) |
| Connection profile (Dimensions) | 3+4 |
| Rated surge voltage (Dimensions) | 8 kV (power contacts) |
| Note (Mechanical characteristics) | For HEAVYCON HC-B6 to B48 housing, HC-M-MHR... hinged retaining frame required, crimp connection, power contacts: CK 4,0-ED..., control contacts: CK 1,6-ED... (crimp contacts not supplied as standard) |
| Couleur (Caractéristiques mécaniques) | light gray |
| Matériau support de contact (Général) | PC |
| Matériau de la surface de contact (Généralités) | Ag |
| Rated voltage (III/3) (Dimensions) | 830 V (power contacts) |
| Series (Mechanical characteristics) | HC-M-03/04 |
| Poids par pièce (emballage exclu) | 9.600 g |
| Contact diameter (Ambient conditions) | 4 mm |
| Normes et réglementations RoHS en Chine | Environmentally friendly use period: unlimited = EFUP-e |
| Connection (Mechanical characteristics) | The module cannot be used simultaneously with HC-B...-TMB-SD-IP65 and HC-B...-TMS-SD-IP65 protective covers. Not suitable for CK1,6-ED-...POF fiber optic contacts. |
| Contact type (Mechanical characteristics) | turned |
| Minimum housing height (Ambient conditions) | 52 mm |
| Section transversale du conducteur (conditions ambiantes) | 1.5 mm² ... 6 mm² (power contacts) |
| Connection method (Mechanical characteristics) | Crimp connection (power contacts) |
| Degré de pollution (Caractéristiques mécaniques) | 3 |
| Cycles d'insertion/retrait (conditions ambiantes) | ≥ 500 |
| Connection cross section AWG (Ambient conditions) | 16 ... 10 (power contacts) |
| Catégorie de surtension (Caractéristiques mécaniques) | III |
| Assembly instructions (Mechanical characteristics) | To ensure correct use, installation in housing with IP54 protection or better is required |
| Number of module slots (Mechanical characteristics) | 1 |
| Indice d'inflammabilité selon la norme UL 94 (Données sur les matériaux) | V0 |
| Diamètre du fil, isolation comprise (conditions ambiantes) | 5 mm (for power contacts) |
| Ambient temperature (operation) (Electrical characteristics) | -40 °C ... 125 °C |
| Stripping length of the individual wire (Ambient conditions) | 9 mm (9.6 mm (4.0 -6.0 mm²)) |
| Indice d'inflammabilité selon la norme UL 94 (Caractéristiques mécaniques) | V0 |