| Paramètre | Valeur |
|---|---|
| GTIN | 4017918893293 |
| Note | Made to Order (non-returnable) |
| Clé de commande | 1605000 |
| page du catalogue | Page 553 (C-4-2015) |
| Unité d'emballage | 1 pc |
| Pays d'origine | DE (Germany) |
| numéro de tarif douanier | 85366990 |
| (Conditions ambiantes) | 8 Nm (35 mm²) |
| Matériel de contact (Général) | Copper alloy |
| Rated current (Dimensions) | 100 A |
| Largeur (Données commerciales clés) | 34.2 mm |
| (Normes et réglementations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Taille (Données commerciales clés) | 49 mm |
| Longueur (Données commerciales clés) | 29.4 mm |
| Connection profile (Dimensions) | 2 |
| Rated surge voltage (Dimensions) | 8 kV |
| Matériau support de contact (Général) | PC |
| Matériau de la surface de contact (Généralités) | Ag |
| Rated voltage (III/3) (Dimensions) | 1000 V |
| Series (Mechanical characteristics) | HC-M-HS |
| Poids par pièce (emballage exclu) | 69.900 g |
| Hexagonal socket (Ambient conditions) | SW 4 |
| Normes et réglementations RoHS en Chine | Environmentally Friendly Use Period = 50 |
| Couple de serrage (conditions ambiantes) | 6 Nm (16 mm²) |
| Connection (Mechanical characteristics) | Note for axial connection methodThe specified conductor cross sections refer to the geometric cross section of the used conductor.The use of conductors with a geometric cross section that deviates greatly from the nominal cross section of the conductor should be checked first.The wiring space of the axial screw technology has been designed for fine strand conductors as per VDE 0295 class 5. Deviating conductor superstructures (e.g. class 6 conductors) must be checked before use.ConnectionIt must be ensured before installation that the ball screw is completely turned back (chamber is open). Twisting the conductors is not allowed. The cores must be pushed up to the end of the contact chamber (until the contact is insulated). Keep the core in this position and tighten it using an Allen key. The required core end must be cut before a reconnection. Tightening the connection screw is allowed only once in order to prevent a breakage of the litz wire. |
| Minimum housing height (Ambient conditions) | 72 mm |
| Section transversale du conducteur (conditions ambiantes) | 16 mm² ... 35 mm² (The cross section specification refers to the geometric cross section of the cable used) |
| Connection method (Mechanical characteristics) | Axial screw connection |
| Connection in acc. with standard (Material data) | CUL |
| Degré de pollution (Caractéristiques mécaniques) | 3 |
| Cycles d'insertion/retrait (conditions ambiantes) | ≥ 500 |
| Connection cross section AWG (Ambient conditions) | 4 ... 2 |
| Catégorie de surtension (Caractéristiques mécaniques) | III |
| Assembly instructions (Mechanical characteristics) | - Use HC housing h >= 72 mm- Connection of wires using a 4 mm Allen wrench- Axial screw connection only for stranded wires- Plug-in connections may only be operated only when there is no load/voltage |
| Number of module slots (Mechanical characteristics) | 2 |
| Indice d'inflammabilité selon la norme UL 94 (Données sur les matériaux) | V0 |
| Diamètre du fil, isolation comprise (conditions ambiantes) | 11.4 mm |
| Ambient temperature (operation) (Electrical characteristics) | -40 °C ... 125 °C |
| Stripping length of the individual wire (Ambient conditions) | 13 mm |
| Indice d'inflammabilité selon la norme UL 94 (Caractéristiques mécaniques) | V0 |
Spécifications techniques et données de performance
Guide d'installation et d'utilisation