| Paramètre | Valeur |
|---|---|
| Assembly procedure:- Strip wire 9.5 mm,- connect the stripped part of the wire through the locking sleeve (for wire diameter > 3.2 mm),- crimp wire (with protracted locking sleeve) with CK2.5...ED crimp contact,- lock the locking sleeve with the crimp contact together with the module's insulating body. | |
| Largeur | 34.2 mm |
| Hauteur | 62 mm |
| Longueur | 29.4 mm |
| Série | HC-M-HV |
| Général | For HEAVYCON housing type B6 to B48, HC-M-MHR... hinged retaining frame required, CK2,5-ED... crimp contacts (crimp contacts not supplied as standard) |
| Application | High-voltage |
| Type de produit | Modular contact insert |
| Tension d'essai | 10 kV AC |
| Note de l'assemblée | Use HC housing h >= 72 mm. Plug-in connections may only be operated only when there is no load/voltage. |
| Courant nominal | 16 A |
| Diamètre de contact | 2.5 mm |
| Matériel de contact | Copper alloy |
| Numérotation des contacts | I, II |
| Profil de connexion | 2 |
| Degré de pollution | 3 |
| Dessin coté | |
| Nombre de positions | 2 |
| Tension de surtension nominale | 15 kV |
| Catégorie de surtension | III |
| Technologie de connexion | Crimp connection |
| Type de matériau de contact | turned |
| Tension nominale (III/3) | 2900 V (Conductor-PE) |
| Minimum housing height | 72 mm |
| Nombre d'emplacements pour modules | 2 |
| Section transversale du conducteur | 0.5 mm² ... 4 mm² |
| Matériau porteur de contact | PC/PTFE |
| matériau de surface de contact | Ag (alternatively Au) |
| Cycles d'insertion/retrait | ≥ 500 |
| Section de connexion AWG | 20 ... 12 |
| Température ambiante (fonctionnement) | -40 °C ... 125 °C |
| Tension nominale des contacts de puissance | 2900/5000 V |
| Indice d'inflammabilité selon la norme UL 94 | V0 |
| Longueur de dénudage du fil individuel | 9.5 mm |
Spécifications techniques et données de performance
Guide d'installation et d'utilisation