| Paramètre | Valeur |
|---|---|
| Crimp connection (PE contact) | |
| Taper | D7 |
| Tests | DIN VDE 0627/86 |
| Largeur | 21 mm |
| Hauteur | 34.8 mm |
| Longueur | 21 mm |
| Série | HC-HS |
| Général | For HC-D7 housing, crimp contacts CK 4,0. Crimp contacts not included in scope of supply. |
| Application | Power |
| Type de produit | Contact insert with a fixed no. of positions |
| Note de l'assemblée | To ensure correct use, installation in housing with IP54 protection or better is required |
| Courant nominal | 40 A |
| Révision de l'article | 04 |
| Diamètre de contact | 4 mm |
| Matériel de contact | Copper alloy |
| Numérotation des contacts | 1 - 2 |
| Couple de serrage | 0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing) |
| Profil de connexion | 3+PE |
| Degré de pollution | 3 |
| Dessin coté | |
| Nombre de positions | 3 |
| Tension de surtension nominale | 6 kV |
| Catégorie de surtension | III |
| Technologie de connexion | Crimp connection |
| Type de matériau de contact | turned |
| Tension nominale (III/3) | 400 V |
| Normes/réglementations | PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |
| Section transversale du conducteur | 1.5 mm² ... 6 mm² |
| Matériau porteur de contact | PC |
| matériau de surface de contact | Ag |
| Cycles d'insertion/retrait | ≥ 500 |
| Section de connexion AWG | 16 ... 10 |
| Température ambiante (fonctionnement) | -40 °C ... 125 °C (including heating up of contacts) |
| Connexion conforme aux normes | IEC / EN |
| Nombre de connexions par position | 1 |
| Constructional and testing regulations | DIN VDE 0627/86 |
| Indice d'inflammabilité selon la norme UL 94 | V0 |
| Longueur de dénudage du fil individuel | 9 mm (2,5 mm² ... 6,0 mm²) |
Spécifications techniques et données de performance