Heures de service : Lundi à vendredi 9h00-18h00
HLC1CM - HLC1CM HL-C1C-M PANASONIC Driver for connecting 2 sensor heads HL-C1 series
En stock Produit phare

HLC1CM

HLC1CM HL-C1C-M PANASONIC Driver for connecting 2 sensor heads HL-C1 series

$0.00USD
3584 en stock
Spécifications clés
Article:Specifications
Poids:Net weight: 300 g approx.
Détails:Controller
Produit:Ultra High-speed Laser Displacement Sensor [CCD Style]
Informations sur le fournisseur
PANASONIC
PANASONIC
Produits : 4316
Habituellement expédié sous 2 à 3 jours ouvrables
Qualité garantie
Livraison rapide
Support technique

Spécifications techniques

ParamètreValeur
ArticleSpecifications
PoidsNet weight: 300 g approx.
DétailsController
ProduitUltra High-speed Laser Displacement Sensor [CCD Style]
Accessoire-
Numéro de pièceHL-C1C-M
Sortie d'alarmePhoto-MOS relay- Maximum load current: 50 mA- Applied voltage: 30 V DC or less (between alarm output and COM)- ON impedance: 35 Ohm or less- Operation time: Max. 2 ms
longueur du câblePower line: Less than 10 m 32.808 ftSignal line: Less than 30 m 98.425 ft
Nom du produitUltra High-speed Laser Displacement Sensor HL-C1(Discontinued)
Taux d'échantillonnageSelectable from 100 micro s / 144 micro s / 200 micro s / 255 micro s / 332 micro s / 498 micro s / 1,000 micro s
Fonctions de maintienSelectable from NORMAL / P-P / PEAK / VALLEY(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Numéro de produitHL-C1C-M
Tension d'alimentation24 V DC plus or minus 10 % including ripple 0.5 V (P-P)
Filtres numériquesHigh pass: OFF, 10 to 2,000 Hz (9 steps)Low pass: OFF, 10 to 2,000 Hz (9 steps)(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Indicateurs : FONCÉSRed LED (lights up upon disabled measurement due to insufficient light at sensor head 1 or 2)
Entrée Zero activéeZero set: ON when voltage (using input voltage: 12 to 24 V DC, maximum input voltage: 30 V DC) is input
Étalonnage : Étendue0.9000 to 1.1000(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Entrée de mise à zéro OFFZero set: OFF when voltage (using input voltage: 12 to 24 V DC, maximum input voltage: 30 V DC) is input
Étalonnage : Décalageplus or minus 20.0000 mm plus or minus 0.787 in(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Consommation de courantWhen 1 sensor is connected: 430 mA approx.When 2 sensors are connected: 550 mA approx.
Indicateurs : BRILLANTSRed LED (lights up upon disabled measurement due to excessive light at sensor head 1 or 2)
Fonctions de calculL plus or minus KA, L plus or minus KB, L plus or minus K (A plus or minus B)A, B: Sensor head 1, Sensor head 2 measurement values, L = plus or minus 999.9999, K = 0.0001 to 99.9999(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Entrée/sortie sérieRS-232C
Tête de capteur ConnectaleMaximum 2 sensor heads
Sortie analogique : CourantOutput current: 4 to 20 mA/F.S. [default setting when diffuse reflective mode is selected (Note 2)]Output range: 0 to 29.5 mA (maximum of 25 mA at max. load impedance)Load impedance: 250 Ohm or less(Note 1) The maximum analog output current will vary with load impedance.(Note 2) If specular reflective mode is selected, then the default setting is 5.6 to 18.4 mA/F.S.
Sortie analogique : TensionOutput voltage: plus or minus 5 V/F.S. [default setting when diffuse reflective mode is selected (Note) ]Output range: -10.9 to +10.9 VOutput current: Max. 2 mA, Output impedance: 50 Ohm(Note) If specular reflective mode is selected, then the default setting is plus or minus 4 V/F.S.
Nombre moyen d'échantillonsOFF, 2 to 32,768 times (16 steps)(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Résultats du jugement (O1, O2)Photo-MOS relay- Maximum load current: 50 mA- Applied voltage: 30 V DC or less (between judgment output and COM)- ON impedance: 35 Ohm or less- Operation time: Max. 2 ms
Indicateurs : Émission laserGreen LED (lights up during laser emission from sensor head 1 or sensor head 2, or immediately before laser emission)
Caractéristiques de températureplus or minus 0.01 % F.S./degrees
Entrée de synchronisation (émission laser)Laser emission stops or continues when voltage (using input voltage: 12 to 24 V DC, maximum input voltage: 30 V DC) is input or there is an open circuit: determined based on input mode selection.
Sortie d'alarme : Fonctionnement de sortieOpened when the amount of light is excessive or insufficient.
Sortie d'alarme : Protection contre les courts-circuitsIncorporated
Résistance environnementale : humidité ambiante35 to 85 % RH, Storage: 35 to 85 % RH
Résistance environnementale : Résistance aux chocs196 m/s2 (20 G approx.) in X, Y and Z directions for 3 times each
Sorties de jugement (O1, O2) : Opération de sortieOpened or closed when the threshold value is reached. Determined based on judgment output mode selection. (The threshold value varies with the hysteresis setting.)
Résistance environnementale : Température ambiante0 to +50 degrees +32 to +122 degrees Fahrenheit (No dew condensation), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
Résistance environnementale : Résistance aux vibrations10 to 55 Hz frequency (period: 1 min.) 0.75 mm 0.030 in amplitude in X,Y and Z directions for 30 min. each
Résultats du jugement (O1, O2) : Catégorie d'utilisationDC-12 or DC-13
Sorties de jugement (O1, O2) : Protection contre les courts-circuitsIncorporated

Description du produit

More details
Caractéristiques principales
  • Qualité de niveau industriel
  • Conforme RoHS
  • Certifié CE
  • Garantie d’un an

Documents du produit

Fiche technique

Spécifications techniques et données de performance

Manuel d'utilisateur

Guide d'installation et d'utilisation

Top