Spécifications clés
Nom:MPM-30-24
État:New
Format:For Printed Circuit
Série:MPM-30
Informations sur le fournisseur
MEANWELL
MEANWELL
Produits : 6448
Habituellement expédié sous 2 à 3 jours ouvrables
Qualité garantie
Livraison rapide
Support technique

Spécifications techniques

ParamètreValeur
NomMPM-30-24
ÉtatNew
FormatFor Printed Circuit
SérieMPM-30
ApprobationsEC, EAC, EN60601 3rd Edition, UL
Puissance (W)31,20
Sous-formatEncapsulated
Largeur (mm)39.00
Hauteur (mm)24.00
Entrée CA Max264,00
Entrée CA Min80,00
ApplicationsIndustrial, Medical, Telecommunications
FabricantMEAN WELL
Type de produitPower supply AC/DC
Isolation (V)4.000,00
Tension de sortie24,00
Puissance de crête (W)Thirty six
Connecteur d'entréePin
Fréquence d'entrée50 Hz, 60 Hz
Contexte long69.50
Description longueMedical power supply for printed circuit board encapsulated.Source certified for medical applications 2x MOPP (patient protection).Encapsulated format for printed circuit boards.Range of universal input80-264vac.47-63Hz.Voltageoutput24vdc.Intensity ofoutput1300mA(1500mA max). Range of output current 0-1300mA according to demand load.Power:31,2 W(36W for 10s).Efficiency typical:90%.Consumption without load<0,075 W.Protection against short circuit, over load, over voltage and temperature.Requires No minimum load.Level of vibration up to 5G.Input class II without grounding. EMI class B.Low leakage current < 80µA to 264vac.Working temperature: from-40up+85 ° Cof ambient temperature. Consult the technical data sheet to see the curves of drift.Dimensions (Length x Width x Height) [mm]:69,5 x 39 x 24.3 years of warranty.Manufacturer: MEAN WELL.The series MPM are power supply certified for medical use with patient protection, 2 x MOPP (means of patient protection). They have a double protection between input and output 2xMOPP.Have a leakage current (contact current) is very low for a greater security in the application. With low power consumption at no load and requires no minimum load. It has been designed for the most demanding applications at the level of vibration (5G). Sources with class II non-grounded. With an excellent heat dissipation and high useful life thanks to its encapsulation.These sources can be used for medical applications BF (body floating) with the necessary considerations of the system and for industrial applications, and information technology. Suitable for portable medical devices, mobile clinics, monitors and instruments for medical examination. Complies with ANSI/AAMI ES60601-1 and IEC/EN60601-1.
Connecteur de sortiePin
Type d'entrée CASingle-phase
Garantie (années)3,00
Pays d'origineChina

Description du produit

More details
Caractéristiques principales
  • Qualité de niveau industriel
  • Conforme RoHS
  • Certifié CE
  • Garantie d’un an

Détails techniques

Medical power supply for printed circuit board encapsulated.