| Paramètre | Valeur |
|---|---|
| 100 V AC ... 109 V AC -15 % ... +10 % (PN= 63 W) | |
| Temps | 28000 h |
| Couleur | green |
| Profondeur | 100 mm |
| Saisir | 4 kV (Test Level 4 - asymmetrical) |
| Largeur | 33 mm |
| rigide | 0.5 mm² ... 2.5 mm² |
| Hauteur | 90 mm |
| Sortir | 2 kV (Test Level 3 - asymmetrical) |
| Actuel | 3.15 A |
| LED éteinte | Supply voltage input AC not present (Off) |
| Tension | 10 V (Test Level 3) |
| Commentaires | Criterion A |
| Fonction | Visual operating state display |
| Position | 1.x |
| flexible | 0.5 mm² ... 2.5 mm² |
| Fréquence | 50 Hz |
| Temps de lever | < 100 ms (UOut= 10 % ... 90 %) |
| EN 61010-1 | II (≤ 3000 m) |
| Efficacité | typ. 88 % (120 V AC) |
| Critère A | Normal operating behavior within the specified limits. |
| Critère B | Temporary impairment to operational behavior that is corrected by the device itself. |
| Critère C | Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements. |
| Température | 40 °C |
| chute de tension | 70 % |
| rigide (AWG) | 20 ... 14 (Cu) |
| Facteur Crest | typ. 3 (120 V AC) |
| Version à capuche | Stainless steel |
| Entrée/Sortie | asymmetrical |
| Type de produit | Power supply |
| Type de montage | DIN rail mounting |
| Sans charge | yes |
| Classe climatique | 3K22 (in accordance with EN 60721-3-3) |
| Identification | 1.1 (), 1.2 (L), 1.3 (N) |
| Courant d'appel | typ. 27 A (at 25 °C) |
| Émission de bruit | EN 55016 |
| Famille de produits | ESSENTIAL POWER |
| Heure de mise en marche | typ. 1 s |
| Texte supplémentaire | 120 V AC |
| Gamme de fréquences | 0 kHz ... 2 kHz |
| Ondulation résiduelle | typ. 50 mVPP(with nominal values) |
| Décharge dans l'air | 8 kV (Test Level 3) |
| Matériau du boîtier | Plastic |
| Altitude maximale | ≤ 5000 m (> 2000 m, Derating: 10 %/1000 m) |
| Nombre de phases | 1.00 |
| Classe de protection | II |
| longueur de dénudage | 6.5 mm |
| Méthode de connexion | Screw connection |
| Sortie de contact | 6 kV (Test Level 3) |
| Écart de contrôle | < 2 % (change in load, static 10 % ... 90 %) |
| fusible secteur de l'appareil | 3.15 A internal (device protection), fast-blow |
| Position de montage | horizontal DIN rail NS 35, EN 60715 |
| Nombre de périodes | 25 periods |
| Puissance de sortie (PN) | 75 W (240 V AC) |
| Choc (opération) | 15 ms, 15 g, per spatial direction (IEC 60068-2-27) |
| Couple de serrage | 0.5 Nm ... 0.6 Nm |
| circuit de protection | Transient protection; Varistor |
| Types de signalisation | LED DC OK – signal state operation (UN= 24 V DC, IOut= IN) |
| Consommation de courant | max. 1.5 A (75 W) |
| Degré de pollution | 2 |
| matériau de verrouillage au pied | Polyamid |
| Plage de tension d'entrée | 110 V AC ... 240 V AC ±10 % (PN= 75 W) |
| Protection contre les courts-circuits | yes |
| Force du champ d'essai | 10 V/m (Test Level 3) |
| Connexion en série | yes, for increased output voltage |
| Degré de protection | IP20 |
| Plage de fréquences (fN) | 50 Hz ... 60 Hz ±10 % |
| Temps de mise en mémoire tampon du réseau | typ. 14 ms (120 V AC) |
| Version avec élément latéral | Aluminum |
| Désignation standard | Electrical safety |
| Instructions de montage | alignable: 0 mm horizontally, 30 mm vertically |
| Tête de vis à entraînement par forme | Slotted L |
| Émission d'interférences | Interference emission in accordance with EN 61000-6-3 (residential and commercial) and EN 61000-6-4 (industrial) |
| LED allumée (verte), courant continu OK | UOUT> 17.5 V (On (green), DC OK) |
| Directive Basse Tension | Conformance with Low Voltage Directive 2014/35/EC |
| Normes/réglementations | EN 61000-3-2 |
| Vibration (fonctionnement) | 10 Hz ... 50 Hz, amplitude ±0.2 mm |
| Connexion en parallèle | yes, for increasing power and redundancy with diode |
| Tension de sortie nominale | 24 V DC |
| Courant de décharge vers PE | < 3.5 mA |
| MTBF (Telcordia SR-332) | > 2800000 h (25 °C) |
| Avec revêtement protecteur | No |
| Émission de bruit conduit | EN 55016 |
| Normes/spécifications | IEC 61010-2-201 (SELV) |
| Protection par fusible intégrée | no |
| résistance de la tension de rétroaction | ≤ 35 V DC |
| Plage de tension d'entrée nominale | 100 V AC ... 240 V AC |
| Courant de sortie nominal (IN) | max. 3.125 A (PN= 75 W) |
| configuration du système d'approvisionnement | TN, TT, IT (PE) |
| Perte de puissance charge nominale max. | < 9 W (230 V AC) |
| Compatibilité électromagnétique | Conformance with EMC Directive 2014/30/EU |
| Intégrale du courant d'appel (I2t) | typ. 0.6 A2s |
| Tension d'isolation entrée / PE | 3.5 kV AC (type test) |
| Tension typique du réseau électrique national | 120 V AC |
| Type de tension d'alimentation | AC |
| Température ambiante (fonctionnement) | -20 °C ... 70 °C (Derating >45°C: 2.5%/K) |
| entrée/sortie de tension d'isolation | 4 kV AC (type test) |
| Distance d'installation droite/gauche | 10 mm / 10 mm |
| Distance d'installation haut/bas | 30 mm / 30 mm |
| Dissipation de puissance maximale à vide | < 1 W (230 V AC) |
| Dissipation de puissance minimale à vide | < 1 W (120 V AC) |
| Exigences CEM en matière d'immunité au bruit | EN 61000-6-2 |
| dissipation de puissance nominale minimale | < 11 W (120 V AC) |
| Température ambiante (stockage/transport) | -40 °C ... 85 °C |
| Disjoncteur recommandé pour la protection de l'entrée | 6 A ... 16 A (Characteristic B, C, D, K or comparable) |
| flexible avec virole et gaine plastique | 0.5 mm² ... 2.5 mm² |
| Réglage de la plage de tension de sortie (USet) | 24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted) |
| flexible avec virole sans gaine plastique | 0.5 mm² ... 2.5 mm² |
| Humidité relative maximale admissible (en fonctionnement) | ≤ 95 % (at 25 °C, non-condensing) |
| Protection contre les surtensions en sortie (OVP) | ≤ 35 V DC |
Spécifications techniques et données de performance
Guide d'installation et d'utilisation