| Paramètre | Valeur |
|---|---|
| • WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product. | |
| Couleur | black |
| Largeur | 26.3 mm |
| Hauteur | 26.3 mm |
| Longueur | 41.5 mm |
| Type de câble | S03 |
| Consignes de sécurité | • WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible. |
| longueur du câble | 300 mm |
| Sans halogène | yes |
| Type de produit | Panel feed-through |
| matériau d'étanchéité | EPDM |
| Famille de produits | SUNCLIX |
| structure de câbles | 84 x 0.30 mm Ø litz wires, tin-plated, 1x bunched |
| surface de contact | Silver Ag |
| Force d'insertion | 45 N ±10 N |
| Révision de l'article | 10 |
| Matériel de contact | Cu |
| résistance à la flamme | no |
| Matériau du boîtier | PPE |
| Classe de protection | II |
| Force de retrait | 250 N ±50 N (when locked) |
| Résistance à l'huile | no |
| Couple de serrage | 1.8 Nm ±0.1 Nm |
| résistance de contact | 0.45 mΩ |
| section transversale du câble | 6 mm² |
| Cable seal material | Elastosil LR 3065/50 |
| Degré de pollution | 2 |
| Dessin coté | |
| Matériau isolant | mPPE |
| Nombre de positions | 1 |
| Tension de test, câble | ≥ 8 kV AC (Spark test online (standard designation)) |
| force d'arrachement du câble | > 80 N |
| Tension nominale (III/2) | 1000 V |
| Fil unique, matériau | Cu |
| Gaine externe, couleur | red, similar to RAL 3000 |
| Tension nominale, câble | 1.8 kV DC (max U (conductor / conductor, ungrounded system)) |
| Gaine extérieure, matériau | PE-X |
| diamètre extérieur du câble | 5.40 mm ±0.15 mm |
| Matériau porteur de contact | PPE |
| matériau de surface de contact | Ag |
| Courant nominal (6,0 mm²) | 40 A |
| Couleur de la partie boîtier | black |
| Groupe de matériaux isolants | III |
| Fil unique, section transversale | 6 mm² |
| Cycles d'insertion/retrait | 100 |
| Tension de surtension nominale (III/2) | 12 kV |
| Température ambiante (assemblage) | -25 °C ... 50 °C |
| Température ambiante (fonctionnement) | -40 °C ... 85 °C |
| Degré de protection (non branché) | IP20 |
| Degré de protection (lorsqu'il est branché) | IP66 / IP68 (2 m / 24 h) |
| Indice d'inflammabilité selon la norme UL 94 | V0 |
| Rayon de courbure minimal, installation fixe | 27 mm (5x Ø) |
| Rayon de courbure minimal, installation mobile | 54 mm (10x Ø) |
| Structure d'un fil de Litz individuel selon la norme VDE 0295 / diamètre du fil le plus petit | 84x0.3 |
Spécifications techniques et données de performance
Guide d'installation et d'utilisation