Heures de service : Lundi à vendredi 9h00-18h00
RPT-160B - RPT-160B MEANWELL AC-DC Triple output Medical Open frame power supply, Output 5VDC / 14A +12VDC / 5A -12VDC ..
En stock Produit phare

RPT-160B

RPT-160B MEANWELL AC-DC Triple output Medical Open frame power supply, Output 5VDC / 14A +12VDC / 5A -12VDC ..

$64.50USD
197 en stock
Spécifications clés
Nom:RPT-160B
État:New
Alarmes:Powerfail, Output OK
Format:Open Format
Informations sur le fournisseur
MEANWELL
MEANWELL
Produits : 6448
Habituellement expédié sous 2 à 3 jours ouvrables
Qualité garantie
Livraison rapide
Support technique

Spécifications techniques

ParamètreValeur
NomRPT-160B
ÉtatNew
AlarmesPowerfail, Output OK
FormatOpen Format
SérieRPT-160
Sortie 1+5
Sortie 2+12
Sortie 3-12
ApprobationsEC, EAC, EN60601 3rd Edition, UL
Puissance (W)98,40
Sous-format5"x3"
Largeur (mm)76.20
Hauteur (mm)34.60
Entrée CA Max264,00
Entrée CA Min90,00
ApplicationsIndustrial, Medical, Telecommunications
FabricantMEAN WELL
Type de produitPower supply AC/DC
Isolation (V)4.000,00
Puissance de crête (W)One hundred forty six
Connecteur d'entréePlug-in
Fréquence d'entrée50 Hz, 60 Hz
Contexte long127.00
Description longueMedical power supply in open format(Open-Frame).Range of universal input90-264vac47-63Hz.Outputs:-12vdc:Minimum intensity of output0.1 To.Maximum output current0,8Amp.+5vdc:Minimum intensity of output0.6 To.Maximum output currentNineAmps.+12vdc:Minimum intensity of output0.2 To.Maximum output current3,4Amps.Power:98,4 WandOne hundred forty sixW with external fan.Source certified for medical applications2 xMOPP(the patient protection).Leakage current < 160µA.Factor corrector, power>0.93to 230vac at full load.Efficiency:84%.Working temperature: from-20up+70ºCof ambient temperature. Consult the technical data sheet to see the curves of drift.Dimensions (Length x Width x Height) [mm]:127 x 76.2 x 34,6.3 years of warranty.Manufacturer: MEAN WELL.The series RPT-160 power supply certified for medical use with patient protection, 2 x MOPP (means of patient protection). They have a double protection between input and output 2xMOPP and protection between input and ground 1xMOPP.Have a leakage current (contact current) is very low for a greater security in the application. Can operate with cooling by free air circulation or provide a higher power through the use of an external fan.
Connecteur de sortiePlug-in
Type d'entrée CASingle-phase
Garantie (années)3,00
Pays d'origineChina
Vous devez charger au minimumYes

Description du produit

More details
Caractéristiques principales
  • Qualité de niveau industriel
  • Conforme RoHS
  • Certifié CE
  • Garantie d’un an

Détails techniques

Medical power supply in open format(Open-Frame).

Documents du produit

Fiche technique

Spécifications techniques et données de performance

Manuel d'utilisateur

Guide d'installation et d'utilisation

Top