| Paramètre | Valeur |
|---|---|
| Nom | RSD-150D-5 |
| État | Recommended Model |
| Format | Box |
| Série | RSD-150 |
| Approbations | EC |
| Puissance (W) | 150,00 |
| Sous-format | IP20 |
| Largeur (mm) | Seventy seven |
| Hauteur (mm) | Thirty six |
| Plage d'entrée | 2:1 |
| Applications | Railway, Industrial, Telecommunications |
| Entrée CC max. | 143,00 |
| Entrée CC min | 67,20 |
| Fabricant | MEAN WELL |
| Type de produit | Dc/DC converters |
| Isolation (V) | 4.000,00 |
| Tension de sortie | 5,00 |
| Puissance de crête (W) | One hundred fifty |
| Plage d'entrée CC | 67,2, 72, 75, 77, 88, 93,6, 100, 110, 143 |
| Connecteur d'entrée | Screw-Type |
| Contexte long | One hundred eighty nine |
| Description longue | Dc/DC converter rail is a regulated isolated output.Converter for railway applications, industrial or telecommunications.Input range67,2-143Vcc(57,6-154Vcc for 1 second). Range rail to 72V input.Output voltage5vdc.Output intensity:30A.Power:150W.Isolation input-output 4000Vcc.Efficiency of the90%.Operating temperature from-40up+70 ° C(see the curve derived in the technical data sheet). 85 ° c for 10 minutes with ventilation by conduction.Dimensions (Length x Width x Height):189 x 77 x 36mm.3 years of warranty.Manufacturer: MEAN WELL.It is a converter designed for railway applications, industrial or telecommunications.Is certified with the regulations for railway EN50155 and EN45545-2 in front of the fire.Can operate up to 55C at full load and 70 ° C at 60% load or 70 ° C ambient temperature with ventilation by driving without losses. Also supports a temperature range of more demanding level rail Tx to 85ºC ambient temperature for 10 minutes with ventilation by driving on a metal surface.This converter semi-encapsulation has been designed for the most demanding applications at the level of vibration, temperature, and humidity. Has a low profile of only 36mm and uses only components prepared for high temperatures as for example capacitors of 105ºC.It has a low noise and ripple, and high efficiency and is protected against reverse polarity at the input. The inrush current is limited by a resistor in series with a MOSFET to reduce the peak starting current to reliably regardless of the ambient temperature.Its output is protected against short-circuits and overloads by limiting output current, this allows you to start loads with a high inrush. |
| Connecteur de sortie | Screw-Type |
| Garantie (années) | 3,00 |
| Pays d'origine | Taiwan |
Spécifications techniques et données de performance
Guide d'installation et d'utilisation