Heures de service : Lundi à vendredi 9h00-18h00
RSD-60H-5 - RSD-60H-5 MEANWELL DC-DC Enclosed converter, Input 40-160VDC, Output 5VDC / 12A, railway standard EN50155, 4..
En stock Produit phare

RSD-60H-5

RSD-60H-5 MEANWELL DC-DC Enclosed converter, Input 40-160VDC, Output 5VDC / 12A, railway standard EN50155, 4..

$0.00USD
3239 en stock
Spécifications clés
Nom (Détails):RSD-60H-5
État (Détails):Recommended Model
Format (Détails):Box
Série (Détails):RSD-60
Informations sur le fournisseur
MEANWELL
MEANWELL
Produits : 6448
Habituellement expédié sous 2 à 3 jours ouvrables
Qualité garantie
Livraison rapide
Support technique

Spécifications techniques

ParamètreValeur
Nom (Détails)RSD-60H-5
État (Détails)Recommended Model
Format (Détails)Box
Série (Détails)RSD-60
Approbations (Détails)EC
Puissance (W) (Détails)60,00
Subformato (Détails)Grid
Largeur (mm) (Détails)60.00
Hauteur (mm) (Détails)25.00
Plage de saisie (Détails)4:1
Applications (Détails)Railway, Industrial, Telecommunications
Entrée CC max. (Détails)160,00
Entrée CC min (Détails)40,00
Fabricant (Détails)MEAN WELL
Type de produit (Détails)Dc/DC converters
Isolement (V) (Détails)4.000,00
Tension de sortie (Détails)5,00
Puissance crête (W) (Détails)Sixty
Connecteur d'entrée (Détails)Screw-Type
Contexte/Détails (Longue durée)128.00
Description longue (Détails)Dc/DC converter Rail is a Regulated Isolated Output.Converter for Railway applications, Industrial or Telecommunications.Input range40-160Vcc(5.75 in-7Vcc for 1 second).Output voltage5vdc.Output intensity12A.Power:60W.Isolation input-output 4000Vcc.Efficiency of the89%.Operating temperature from-40up+70 ° C(see the curve derived in the technical data sheet). 85 ° c for 10 minutes with ventilation by conduction.Dimensions (Width x Height x depth):128 x 60 x 25mm.3 years of warranty.Manufacturer: MEAN WELL.This model has a hold time (hold-up time) to the output of10ms at full load.It is a converter designed for railway applications, industrial or telecommunications.Is certified with the regulations for railway EN50155 and EN45545-2 in front of the fire.Can operate up to 55C at full load and 70 ° C at 60% load or 70 ° C ambient temperature with ventilation by driving without losses. Also supports a temperature range of more demanding level rail Tx to 85ºC ambient temperature for 10 minutes with ventilation by driving on a metal surface.This converter semi-encapsulation has been designed for the most demanding applications at the level of vibration, temperature, and humidity. Has a low profile of only 25mm.Its output is protected against short-circuits and overloads by limiting output current, this allows you to start loads with a high inrush.
Connecteur de sortie (Détails)Screw-Type
Garantie (années) (détails)3,00
Pays d'origine (détails)Taiwan

Description du produit

More details
Caractéristiques principales
  • Qualité de niveau industriel
  • Conforme RoHS
  • Certifié CE
  • Garantie d’un an

Détails techniques

Dc/DC converter Rail is a Regulated Isolated Output.