| Paramètre | Valeur |
|---|---|
| Ventilateur | Yes |
| Nom | RST-5000-36 |
| Alarmes | Over Temperature, mains Failure, Output OK |
| Format | Box |
| Série | RST-5000 |
| Approbations | CE, UL |
| Puissance (W) | 4.968,00 |
| Sous-format | Grid |
| Largeur (mm) | Two hundred eleven |
| Hauteur (mm) | 83.5 |
| Entrée CA Max | 530,00 |
| Entrée CA Min | 340,00 |
| Applications | Industrial, Telecommunications |
| Fabricant | MEAN WELL |
| Type de produit | Power supply AC/DC |
| Isolation (V) | 3.000,00 |
| Tension de sortie | 36,00 |
| Puissance de crête (W) | Four thousand nine hundred sixty eight |
| Connecteur d'entrée | Screw-Type |
| Fréquence d'entrée | 50 Hz, 60 Hz |
| Contexte long | Four hundred sixty |
| Description longue | Switch mode power supply three-phase.Format in box.Input rangethree-phase star with neutral3x340-530Vcaor input three-phase delta without neutral 3 x 196-305Vca. 47-63Hz.You can also operate with single phase input from 196-305Vca (consult the technical data sheet in the attached documents).You need the neutral to operate on three-phase to 380V.Output voltage36Vcc. Adjustable by potentiometer (35-43,2 Dc).Output intensityOne hundred thirty EIGHT. Range of output current 0-138 according to demand load.Factor Corrector, Power>0,95.Power:Four thousand nine hundred sixty eightW.Efficiency typical:90%.Remote on / off.Additional output of 12V 0,1 A for power-on and remote shutdown.Function of sensing to compensate the voltage drop in the cables up to 0.3 V.Alarm output voltage to the correct DC-Ok, power supply failure AC-Fail and fan failure Fan-Fail.Voltage and Current programmable Output.Paralelizable up to 4 units.Working temperature: from-30up+70 ° Cof ambient temperature. Consult the technical data sheet to see the curves of drift.Dimensions (Length x Width x Height) [mm]:460 x 211 x 83.5.5 years of warranty.Manufacturer: MEAN WELL.The series RST-5000 switching power supplies with three phase input. Have a high efficiency and power factor.We can parallelize up to 4 units to increase power or achieve redundancy.The output voltage can be set between 20%and 120% of the nominal output voltage by an external signal of 1-6v.The output current can also be programmed between 20% and 100% of its value payroll with an external signal of 1-5vdc.The behavior before an over-load can be set to keep the current constant by reducing the output voltage or power-off after 5 seconds of the overload. |
| Connecteur de sortie | Screw-Type |
| Type d'entrée CA | Three-Phase + Neutral |
| Garantie (années) | 5,00 |
| Pays d'origine | Taiwan |
Spécifications techniques et données de performance
Guide d'installation et d'utilisation