Heures de service : Lundi à vendredi 9h00-18h00
S8VM-10024 - S8VM-10024 196139 OMRON Power & 100W / 24V / 4.5A Open
En stock Produit phare

S8VM-10024

S8VM-10024 196139 OMRON Power & 100W / 24V / 4.5A Open

$0.00USD
3855 en stock
Informations sur le fournisseur
OMRON
OMRON
Produits : 41472
Habituellement expédié sous 2 à 3 jours ouvrables
Qualité garantie
Livraison rapide
Support technique

Description du produit

More details
Caractéristiques principales
  • Qualité de niveau industriel
  • Conforme RoHS
  • Certifié CE
  • Garantie d’un an

Détails techniques

CJ-Series Analog I/O UnitCJ1W-AD/DA/MADConsistent Microsecond Throughput: Models with Direct Conversion Join the Lineup• Analog Input Units for converting analog input signals into binary data• Analog Output Units for converting binary data into analogoutput signalsCSM_CJ1W-AD_DA_MAD_DS_E_4_1CJ1W-AD042CJ1W-DA042VFeaturesAnalog Input Units• Input up to eight analog signals with one Unit.• Functions include line disconnection detection, averaging, peak value holding, offset/gain adjustment, and scaling. (Offset/gain adjustment is not supported by the CJ1W-AD042. Scaling is supported only by the CJ1W-AD042.)• High-speed A/D conversion in 20 μs/point with direct conversion function * (CJ1W-AD042 only).Analog Output Units• Output up to eight analog signals with one Unit.• Functions include output holding, offset/gain adjustment, and scaling. (Offset/gain adjustment is not supported by the CJ1W-DA042V. Scaling is supported only by the CJ1W-DA08V/DA08C/DA042V.)• High-speed D/A conversion in 20 μs/point with direct conversion function * (CJ1W-DA042V only).Analog I/O Units• Input up to four analog signals and output up to two analog signals with one Unit.• Functions include line disconnection detection, input averaging, scaling, input peak value holding, output holding, ratio conversion, and offset/gain adjustment.* Direct Conversion Instructions for High-speed type can be used to create a consistent response time from input through data processing and output. With the Machine Automation Controller NJ-series, the direct conversion function cannot be used. This function is supported only by the CJ-series CPU Unit.System ConfigurationCPU Unit Analog Input UnitAnalog Output UnitSYSMACRUNAD081-V1DA041CJ1G-CPU44 ERR/ALMRUNRUNPROGRAMMABLE CONTROLLERINH PRPHL COMMERC ERH ADJB1 A1ERC ERH ADJB1 A1OPENMCPWR BUSYMACH No. x10 1x10 0MACH No. x10 1x10 0PERIHERALMODEMODEPORTTemperatureSensorRegulatorPressureSpeedFlow rateVoltagePreampServo- controllerVariable speed controller(Temperature control) M(Position control)MCurrentPowerPower factorTransducerChart recorder(Speed control)SensorNote: The above diagram is an installation example for the CJ1W-AD081-V1 Analog Input Units and CJ1W-DA041 Analog Output Units.1

Documents du produit

Fiche technique

Spécifications techniques et données de performance

Manuel d'utilisateur

Guide d'installation et d'utilisation

Top