| Paramètre | Valeur |
|---|---|
| FKM | |
| Note | In line with |
| Matériel | Zinc die-cast (nickel-plated) |
| Application | Railway applications |
| Conception de la tête | Socket |
| Type de fil | M12 |
| Type de produit | Panel mounting base |
| Note de l'assemblée | Spacing between the top edge of the PCB and the back of the front plate: 6 mm |
| Type de montage | Rear mounting M15 x 1 Spacing between the top edge of the PCB and the back of the front plate: 6 mm |
| matériau d'étanchéité | FKM |
| Révision de l'article | 05 |
| Type de filetage de tête | M12 |
| Méthode de connexion | THR solder connection |
| Type de verrouillage de la tête | SPEEDCON |
| Couple de serrage | 1.5 ... 2 Nm |
| Notes sur le fonctionnement | The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. |
| Informations sur la commande : | Lock nut is included in the scope of delivery |
| Degré de protection | IP67 (correctly plugged in and locked) |
| Désignation standard | M12 connector |
| Normes/spécifications | IEC 61076-2-101 |
| Cycles d'insertion/retrait | > 100 |
| Matériau pour raccord à vis | Zinc die-cast, nickel-plated |
| Température ambiante (fonctionnement) | -25 °C ... 85 °C (Plug / socket) |
| Degré de protection (lorsqu'il est branché) | IP67 (correctly plugged in and locked) |
Spécifications techniques et données de performance
Guide d'installation et d'utilisation