| Paramètre | Valeur |
|---|---|
| IP20 (Not plugged in) | |
| Codage | T |
| Protégé | no |
| Application | Power |
| Conception de la tête | Socket |
| Type de capteur | Power |
| Type de fil | M12 |
| Type de produit | Contact insert |
| Sceau présent | no |
| Type de montage | PCB mounting |
| Révision de l'article | 00 |
| Matériel de contact | CuZn |
| Type de filetage de tête | M12 |
| Méthode de connexion | THR solder connection |
| Sortie du câble de tête | straight |
| Type d'emballage | Tray |
| résistance de contact | ≤ 3 mΩ |
| Courant nominal IN | 12 A |
| Tension nominale UN | 63 V |
| Notes sur le fonctionnement | The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. |
| Degré de pollution | 3 |
| Nombre de positions | 4 |
| Tension de surtension nominale | 1.5 kV |
| Degré de protection | IP67 (correctly plugged in and locked) |
| Catégorie de surtension | III |
| Type/catégorie de signal | Power |
| Désignation standard | M12 connector |
| résistance d'isolation | ≥ 100 MΩ |
| Matériau porteur de contact | PA 4T |
| matériau de surface de contact | Au |
| Cycles d'insertion/retrait | > 100 |
| Température ambiante (fonctionnement) | -25 °C ... 105 °C |
| Degré de protection (lorsqu'il est branché) | IP67 (correctly plugged in and locked) |
| Indice d'inflammabilité selon la norme UL 94 | V0 |
Spécifications techniques et données de performance
Guide d'installation et d'utilisation