| Paramètre | Valeur |
|---|---|
| PL | d (2A@230VAC; 1 comm. @30s)e (2A@230VAC; 1 comm. @60s)e (2A@230VAC; 1 comm. @1h)e (2A@230VAC; 1 comm. @24h)d (0,5A@230VAC; 1 comm. @30s)d (0,5A@230VAC; 1 comm. @60s)e (0,5A@230VAC; 1 comm. @1h)e (0,5A@230VAC; 1 comm. @24h) |
| CFF | 80% |
| SIL | 4 |
| PFHd | 2,08E-08 (2A@230VAC; 1 comm. @30s)1,71E-08 (2A@230VAC; 1 comm. @60s)6,588E-09 (2A@230VAC; 1 comm. @1h)6,42E-09 (2A@230VAC; 1 comm. @24h)5,03E-08 (0,5A@230VAC; 1 comm. @30s)2.80E-08 (0,5A@230VAC; 1 comm. @60s)6,76E-09 (0,5A@230VAC; 1 comm. @1h) |
| Taper | 4 |
| Dcavg | 98,89% (2A@230VAC; 1 comm. @30s)98,78% (2A@230VAC; 1 comm. @60s)98,78% (2A@230VAC; 1 comm. @1h)96,25% (2A@230VAC; 1 comm. @24h)98,94% (0,5A@230VAC; 1 comm. @30s)98,89% (0,5A@230VAC; 1 comm. @60s)97,01% (0,5A@230VAC; 1 comm. @1h)96,28% (0,5A@23 |
| MTTFd | 25,97 (2A@230VAC; 1 comm. @30s)49,42 (2A@230VAC; 1 comm. @60s)100 (2A@230VAC; 1 comm. @1h)100 (2A@230VAC; 1 comm. @24h)13,25 (0,5A@230VAC; 1 comm. @30s)25,97 (0,5A@230VAC; 1 comm. @60s)100 (0,5A@230VAC; 1 comm. @1h)100 (0,5A@230VAC; 1 comm. @2 |
| SILCL | 4 |
| Approbations | CE, cULus, TÜV |
| Dimensions | 35 x 99 x 114,5 mm |
| Relations | terminals |
| Description | Cat. 4 Safety Module with integrated Muting function |
| Type de sortie | 2 x relay NO (OSSD safety output)1 x NO, 100mA, 24V (System Status) |
| Utilisable avec | Safety light curtains: LS2, LS4, LP4 |
| Courant de charge | 2A @ 250V |
| temps de réponse | ≤ 20ms |
| Compatibilité CEM | According to 2014/30/EU Directive |
| Tension de fonctionnement | 24Vdc ± 20% |
| Délai d'expiration de la priorité | 15 min |
| Consommation d'énergie | ≤ 5W |
| Principe de fonctionnement | Control unit |
| Sortie de lampe de mise en sourdine | 24V - 0,5 … 5W |
| Fonctions disponibles | Manual/Automatic Restart, EDM, System Status, Muting, Override |
| Degré de protection | IP20 |
| Température de fonctionnement | 0°C … + 55°C |
| Longueur du câble (capteurs) | ≤ 100m |
| Distance de détection nominale | According to the sensors used:LS2 up to 12mLS4 up to 20m |
| Nombre maximal de capteurs de mise en sourdine | 2 x PNP-NO |
| Nombre maximal de capteurs connectés | 1 x LS2/LS4 receiver |
| Longueur du câble (alimentation/sortie) | ≤ 100m |
Spécifications techniques et données de performance
Guide d'installation et d'utilisation