Heures de service : Lundi à vendredi 9h00-18h00
SFC14EX - SFC14EX SF-C14EX PANASONIC Safety sensor accessory
En stock Produit phare

SFC14EX

SFC14EX SF-C14EX PANASONIC Safety sensor accessory

$0.00USD
3551 en stock
Spécifications clés
Article:Specifications
PFHD:1.66 × 10-10(Note:Probability of dangerous failure per hour)
MTTFD:100 years or more(Note:Mean time to dangerous failure (in years))
Poids:Net weight: 250 g approx.
Informations sur le fournisseur
PANASONIC
PANASONIC
Produits : 4316
Habituellement expédié sous 2 à 3 jours ouvrables
Qualité garantie
Livraison rapide
Support technique

Spécifications techniques

ParamètreValeur
ArticleSpecifications
PFHD1.66 × 10-10(Note:Probability of dangerous failure per hour)
MTTFD100 years or more(Note:Mean time to dangerous failure (in years))
PoidsNet weight: 250 g approx.
DétailsApplicantion expansion unit for the SF4B series
ProduitExclusive Control Unit for Safety Light Curtain
MatérielEnclosure: ABS
Numéro de pièceSF-C14EX
Nom du produitExclusive Control Unit for Safety Light Curtain SF-C10
Tension d'alimentation24 V DC plus or minus 10 % Ripple P-P 10 % or less
Numéro de produitSF-C14EX
Humidité ambiante30 to 85 % RH, Storage: 30 to 95 % RH
Catégorie de contrôleISO 13849-1 (EN ISO 13849-1, JIS B 9705-1) compliance up to Category 4, PLe standards
résistance aux chocs30 G acceleration in X, Y and Z directions three times each
Sortie de lampe de mise en sourdineApplicable muting lamp: 24 V DC, 3.6 to 30 W (L1, L2 of each unit)
Température ambiante-10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158 ℉
Terminal de connexionDetachable spring-cage terminal
Consommation de courant0.2 A or less (Excluding Safety light curtain and other external connecting device)
résistance aux vibrations10 to 55 Hz frequency, 0.35 mm0.014 indouble amplitude in X, Y and Z directions for two hours each
résistance d'isolation20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure
Normes applicables : JaponJIS B 9704-1 (Type 4), JIS B 9705-1 (Category 4, PLe)
Conformité à la directive de marquage CEMachinery Directive, EMC Directive, RoHS Directive
Normes applicables : Europe (UE)EN 55011, EN ISO 13849-1 (Category 4, PLe)
Barrières immatérielles de sécurité connectablesSF4B / SF4B-Gseries(Note:The handy-controllerSFB-HC(optional) cannot be used withSF-C14EX-01.)
Normes applicables : Amérique du NordANSI/UL 61496-1 (Type 4), UL 1998 (Class 2)
Sortie de lampe de mise en sourdine : circuit de protectionIncorporated
Normes applicables : Norme internationaleIEC 61496-1 (Type 4), IEC 61496 (Type 4),ISO 13849-1 (Category 4, PLe)
Résistance environnementale : Degré de protectionEnclosure: IP40Terminal: IP20
Résistance environnementale : rigidité diélectrique, tension1,000 V AC for one min. between all supply terminals connected together and enclosure
Sorties de sécurité (Sortie de sécurité 1, Sortie de sécurité 2, Sortie de sécurité 3)PNP open-collector transistor 2 outputs × 3 or NPN open-collector transistor 2 outputs × 3 (selectable using a slider switch)<When PNP output is selected>・Maximum source current: 200 mA・Applied voltage: same as supply voltage(between the safety output and +V)・Residual voltage: 2 V or less (at 200 mA source current)<When NPN output is selected>・Maximum sink current: 200 mA・Applied voltage: same as supply voltage(between the safety output and 0 V)・Residual voltage: 2 V or less (at 200 mA sink current)
Sorties de sécurité (Sortie de sécurité 1, Sortie de sécurité 2, Sortie de sécurité 3) : Temps de réponseOFF response: 14 ms or less (Safety output 1 and 2: including the response time of the Safety light curtain)ON response: 90 ms or less (auto-reset) / 140 ms or less (manual reset) (Note)(Note) The auto-reset cannot be used with safety output 3.
Sorties auxiliaires (Sortie auxiliaire 1, Sortie auxiliaire 2, Sortie auxiliaire 3, Sortie auxiliaire 4)PNP open-collector transistor × 3 or NPN open-collector transistor × 3 (selectable using a slider switch)<When PNP output is selected>・Maximum source current: 60 mA・Applied voltage: same as supply voltage(between the auxiliary output and +V)・Residual voltage: 2 V or less (at 60 mA source current)<When NPN output is selected>・Maximum sink current: 60 mA・Applied voltage: same as supply voltage(between the auxiliary output and 0 V)・Residual voltage: 2 V or less (at 60 mA sink current)
Sorties de sécurité (Sortie de sécurité 1, Sortie de sécurité 2, Sortie de sécurité 3) : Mode de fonctionnement (Fonctionnement de sortie)Safety output 1: ON when the safety light curtain is in light receiving condition, OFF when the safety light curtain is in light interrupted condition (Note 3)Safety output 2: ON when the safety light curtain is in light receiving condition or the muting function is validOFF when the safety light curtain is in light interrupted condition and the muting function is invalid (Note 3)Safety output 3: ON when the emergency stop is invalid, OFF when the emergency stop is valid
Sorties de sécurité (Sortie de sécurité 1, Sortie de sécurité 2, Sortie de sécurité 3) : Circuit de protection (Protection contre les courts-circuits)Incorporated
Sorties auxiliaires (Sortie auxiliaire 1, Sortie auxiliaire 2, Sortie auxiliaire 3, Sortie auxiliaire 4) : Mode de fonctionnement (Fonctionnement en sortie)Auxiliary output 1: ON when the muting function is invalid, OFF when the muting function is validAuxiliary output 2: ON when the override function is invalid, OFF when the override function is validAuxiliary output 3: ON when the muting lamp is normal, OFF when the muting lamp is errorAuxiliary output 4: ON when the light curtain is in light interrupted condition, OFF when the light curtain is in light receiving condition(Note:The auxiliary output incorporated in theSF4Bseries is output.)
Sorties auxiliaires (Sortie auxiliaire 1, Sortie auxiliaire 2, Sortie auxiliaire 3, Sortie auxiliaire 4) : Circuit de protection (Protection contre les courts-circuits)Incorporated

Description du produit

SF-C14EX_Exclusive Control Unit for Safety Light Curtain_Exclusive Control Unit for Safety Light Curtain SF-C10_Applicantion expansion unit for the SF4B series
Caractéristiques principales
  • Qualité de niveau industriel
  • Conforme RoHS
  • Certifié CE
  • Garantie d’un an

Documents du produit

Fiche technique

Spécifications techniques et données de performance

Manuel d'utilisateur

Guide d'installation et d'utilisation

Top