| Paramètre | Valeur |
|---|---|
| Article | Specifications |
| Remarque | (Note:)measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20℃ +68℉. |
| Poids | Net weight: 30 g approx., Gross weight: 125 g approx. |
| Détails | Discrete wire type |
| Afficher | 4 digits + 4 digits 3-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation) |
| Produit | Dual Display Digital Pressure Sensor [For Gas] |
| Matériel | Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Pressure port: Stainless steel (SUS303) , Mounting threaded part: Brass (nickel plated), Switch part: Silicone rubber |
| Protection | IP40(IEC) |
| Accessoires | CN-14A-C2 (Connector attached cable 2 m6.562 ft): 1 pc. |
| Numéro de pièce | DP-102ZL3-M-P |
| longueur du câble | Total length up to 20 m65.617 ft(Condition of CE compliance less than 20 m65.617 ft)is possible with 0.3 mm2, or more, cable. |
| Nom du produit | Dual Display Digital Pressure Sensor [For Gas] DP-100L |
| orifice de pression | M5 female thread |
| Numéro de produit | DP-102ZL3-M-P |
| Tension d'alimentation | 12 to 24 V DC ±10 % Ripple P-P 10 % or less |
| Humidité ambiante | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Fluide applicable | Non-corrosive gas |
| Indicateur de sortie | Orange LED(Output operation indicator 1: Flashes during IO-Link communication, Lights up when the control output is ON during non-IO-Link communication (synchronized with the output operation indicator 2)Output operation indicator 2: Lights up when the control output is ON) |
| résistance aux chocs | 100 m/s2acceleration (10 G approx.) in X, Y and Z directions three times each |
| Type de pression | Gauge pressure |
| Méthode de connexion | Connector |
| Consommation d'énergie | Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)ECO mode: 480 mW or less at STD (Current consumption 20 mA or less at 24 V supply voltage)360 mW or less at FULL (Current consumption 15 mA or less at 24 V supply voltage) |
| Plage de pression définie | -0.101 to +1.010MPa |
| Température ambiante | -10 to +50℃+14 to +122 ℉(No dew condensation or icing allowed), Storage: -10 to +60℃+14 to +140 ℉ |
| Sortie de contrôle (DO) | PNP open-collector transistor•Maximum source current: 50 mA• Applied voltage: 30 V DC or less (between output and +V)• Residual voltage: 2 V or less (at 50 mA source current) |
| Plage de pression nominale | -0.100 to +1.000 Mpa |
| résistance aux vibrations | 10 to 500 Hz frequency, 3 mm0.118 indouble amplitude or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each(when panel or flat attachment is mounted: 10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each) |
| résistance d'isolation | 50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure |
| tenue en tension | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| résistance à la pression | 1.5MPa |
| caractéristiques de température | Within ±1 % F.S.(at +20℃+68℉) |
| Sortie de contrôle (DO) : Hystérésis | Minimum 1 digit (variable) |
| Sortie de contrôle (DO) : Répétabilité | ±0.2 % F.S. (within ±2 digits) |
| Sortie de contrôle (DO) : Temps de réponse | 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation |
| Affichage : Plage de pression affichable | -0.101 to +1.010MPa |
| Sortie de communication (C/Q) : Débit en bauds | COM3 (230.4 kbps)(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO). |
| Sortie de contrôle (DO) : Fonctionnement de sortie | N.O./N.C. (selectable by key operation) |
| Sortie de communication (C/Q) : Données de traitement | 4 byte(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO). |
| Conformité réglementaire et certification | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Certification |
| Sortie de commande (DO) : Protection contre les courts-circuits | Incorporated |
| Sortie de communication (C/Q) : Temps de cycle minimal | 1.0ms(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO). |
| Sortie de communication (C/Q) : communication IO-Link | IO-Link Specification V1.1(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO). |
| Sortie de contrôle (DO) : Fonctionnement de sortie Modes de sortie | EASY mode / Hysteresis mode / Window comparator mode |