| Paramètre | Valeur |
|---|---|
| Article | Specifications |
| Câble | 0.2 mm26-core cabtyre cable, 2 m 6.562 ft long |
| Poids | Net weight: 65 g approx., Gross weight: 110 g approx. |
| Détails | Controller |
| Produit | Electrostatic Sensor |
| Matériel | Enclosure: Heat-resistant ABS, Case cover: Polycarbonate, Mode key: Acrylic, Jog switch: Heat-resistant ABS |
| Linéarité | plus or minus0.5 % F.S.(Note) F.S. is 2,000 V (–1,000 V to 1,000 V) for the plus or minus1 kV range mode and 4,000 V (–2,000 V to 2,000 V) for the plus or minus2kV range mode.(Note) The values given are for when the measured potential is plus or minus200 V or less in the plus or minus1 kV range mode and plus or minus400 V or less in the plus or minus2kV range mode.If the measured potentials are outside these values, the values will be equal to the displayed values plus or minus5 %.(Note) In order to satisfy the linearity specifications for the analog output, do not use the judgment output. |
| Numéro de pièce | EF-S1C |
| Nom du produit | Electrostatic Sensor EF-S1 |
| Sortie analogique | Analog voltage• Output voltage: 1 to 5 V• Output impedance: 100 Ohm approx.(Note) In order to satisfy the linearity specifications for the analog output, do not use the judgment output. |
| Répétabilité | plus or minus0.3 % F.S.(Note) F.S. is 2,000 V (–1,000 V to 1,000 V) for the plus or minus1 kV range mode and 4,000 V (–2,000 V to 2,000 V) for the plus or minus2kV range mode. |
| Numéro de produit | EF-S1C |
| Tension d'alimentation | 24V DC plus or minus10 % |
| rallonge de câble | Extension up to total 10 m 32.808 ft is possible with 0.3 mm2, or more, cable. |
| Humidité ambiante | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Température ambiante | –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: –20 to +70 ℃ – 4 to +158 ℉ |
| Consommation de courant | Normal operation: 50 mA or less, ECO mode: 40 mA or less |
| Tête de capteur applicable | EF-S1HS |
| Affichage de la plage (mode portée) | –1,000 to 1,000 (plus or minus1 kV range mode)–1,999 to 1,999 (plus or minus2kV range mode)(Note) The display range (measurement range) is switched automatically when the measurement distance setting is changed at the controller. |
| Sortie analogique : Temps de réponse | 20 ms, 30 ms (STD), 110 ms, 210 ms, 410 ms, 810 ms switching method |
| caractéristiques de température | 0.05 % F.S./℃(Note) F.S. is 2,000 V (–1,000 V to 1,000 V) for the plus or minus1 kV range mode and 4,000 V (–2,000 V to 2,000 V) for the plus or minus2kV range mode.(Note) The values given are for when the measured potential is plus or minus200 V or less in the plus or minus1 kV range mode and plus or minus400 V or less in the plus or minus2kV range mode.If the measured potentials are outside these values, the values will be 0.5 %/℃ of the displayed values. |
| Entrée de synchronisation / Entrée de réglage du zéro | NPN non-contact input• Signal conditionHigh: +V or open,Low: 0 to +2 V (source current 0.5 mA or less)• Input impedance: 10 kOhm approx. |
| Sorties de jugement (SORTIE 1, SORTIE 2) | NPN open-collector transistor• Maximum sink current: 100 mA• Applied voltage: 30 V DC or less (between judgment output and 0 V)• Residual voltage: 1.5 V or less (at 100 mA sink current) |
| Directives conformes au marquage CE | EMC Directive, RoHS Directive |
| Sorties du jugement (OUT 1, OUT 2) : Temps de réponse | 10 ms, 20 ms (STD), 100 ms, 200 ms, 400 ms, 800 ms switching method |
| Sorties de jugement (OUT 1, OUT 2) : Opération de sortie | OUT1: +potential measurement output or window comparator outputOUT2: –potential measurement output or error output |
| Sorties de jugement (OUT 1, OUT 2) : Protection contre les courts-circuits | Incorporated |