| Paramètre | Valeur |
|---|---|
| Article | Specifications |
| Câble | 0.3 mm23-core cabtyre cable, 2 m6.562 ftlong |
| Sortir | NPN open-collector transistor- Maximum sink current: 100 mA- Applied voltage: 30 V DC or less (between output and 0 V)- Residual voltage: 1 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) |
| Poids | Net weight: 150 g approxGross weight: 200 g approx |
| Détails | NPN output |
| Produit | Adjustable Range Reflective Photoelectric Sensor |
| Matériel | Enclosure: Polyalylate and Polyethylene terephthalateLens: Polyalylate |
| Accessoire | Adjusting screwdriver: 1 pc. |
| Hystérèse | 10 % or less of operation distance (With white non-glossy paper) |
| Protection | IP67 (IEC) |
| Numéro de pièce | EQ-34-J |
| Nom du produit | Adjustable Range Reflective Photoelectric Sensor EQ-30 |
| Répétabilité | Along sensing axis: 10 mm0.394 inor less, Perpendicular to sensing axis: 1 mm0.039 inor less (with white non-glossy paper) |
| temps de réponse | 2 ms or less |
| Numéro de produit | EQ-34-J |
| Tension d'alimentation | 10 to 30 V DC Ripple P-P 10 % or less |
| rallonge de câble | Extension up to total 100 m328.084 ftis possible with 0.3 mm2, or more, cable. |
| Plage réglable | 0.2 to 2 m0.656 to 6.562 ft(Note) The adjustable range stands for the maximum sensing range which can be set with the adjuster.The sensor can detect an object 0.1 m0.328 ft, or more, away. |
| Humidité ambiante | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Élément émetteur | Infrared LED (Peak emission wavelength: 880 nm0.035 mil, modulated) |
| Degré de pollution | 3 (Industrial environment) |
| résistance aux chocs | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Régulateur de distance | 2-turn mechanical adjuster with pointer |
| Éclairage ambiant | Incandescent light: 3,000 ℓx or less at the light-receiving face |
| Température ambiante | -20 to +55 ℃-4 to +131 ℉(No dew condensation or icing allowed), Storage: -25 to +70 ℃-13 to +158 ℉ |
| Consommation de courant | 50 mA or less |
| Indicateur de fonctionnement | Red LED (lights up when the output is ON) |
| Indicateur de stabilité | Green LED (lights up under stable light received condition or stable dark condition) |
| résistance aux vibrations | 10 to 55 Hz frequency, 1.5 mm0.059 indouble amplitude (10 G max.) in X, Y and Z directions for two hours each |
| résistance d'isolation | 20 MOhm , or more, with 250 V megger between all supply terminals connected together and enclosure |
| Sortie : Opération de sortie | Switchable either Detection-ON or Detection-OFF |
| tenue en tension | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Résultat : Catégorie d'utilisation | DC-12 or DC-13 |
| Conformité à la directive de marquage CE | EMC Directive, RoHS Directive |
| Sortie : Protection contre les courts-circuits | Incorporated |
| Fonction de prévention automatique des interférences | Incorporated(Note) Detection may become unstable depending on the setting conditions or the sensing objects. After setting up this product, make sure to check operations using actual sensing objects. |
| Portée de détection (avec du papier blanc non brillant à une distance de réglage de 2 m 6,562 pi) | 0.1 to 2 m0.328 to 6.562 ft |
Spécifications techniques et données de performance
Guide d'installation et d'utilisation