| Paramètre | Valeur |
|---|---|
| Article | Specifications |
| Câble | Cable with a connector, 0.5 m1.640 ftlong |
| Poids | Net weight: 120 g approx. |
| Détails | Spot type |
| Produit | Ultra-compact Ionizer |
| Matériel | Enclosure: PPS, Cover: Stainless steel, Discharge needle: Tungsten |
| Accessoires | Connector for wiring: 1 set [Manufactured by Molex: Housing (5557-08R), Terminal (5556TL)] |
| Équilibre ionique | plus or minus10 V or less(Note) A typical sample applied with a supply voltage of 24 V, a distance of 100 mm3.937 infrom the front surface of the air flow outlet and a pressure of 0.25 MPa while the shower nozzle is in use. (Measured on a sample left in the atmosphere at a relative humidity of 65 % RH or less for 24 hours or more.) |
| Numéro de pièce | ER-VS02 |
| Sortie d'erreur | NPN open-collector transistor• Maximum sink current: 50 mA• Applied voltage: 30 V DC or less (between error output and 0 V)• Residual voltage: 1 V or less (at 50 mA sink current) |
| Nom du produit | Ultra-compact Ionizer ER-V |
| Numéro de produit | ER-VS02 |
| Tension d'alimentation | 24 V DC plus or minus10 % |
| Humidité ambiante | 35 to 65 % RH |
| Fluide applicable | Air (dried clean air)(Note) The air is dried (dew point: equivalent of –20 ℃ – 4 ℉) and filtered (mesh-size: equivalent of 0.01 microm0.0004 mil) air. |
| Méthode de décharge | High frequency AC method |
| génération d'ozone | 0.03 ppm or less(Note) A typical sample applied with a power voltage of 24 V, a distance of 300 mm11.811 infrom the front surface of the air flow outlet and a pressure of 0.25 MPa while the shower nozzle is in use. |
| Débit d'air fourni | 500 liter/min. (ANR) or less(Note) The applicable pressure range depends on the nozzle to be used. |
| Plage de pression atmosphérique | 0.05 to 0.7 MPa(Note) The applicable pressure range depends on the nozzle to be used. |
| Température ambiante | 0 to +55 ℃+32 to +131 ℉(No dew condensation allowed) |
| délai de retrait des frais | 1 sec. or less (plus or minus1,000 V to plus or minus100 V)(Note) A typical sample applied with a supply voltage of 24 V, a distance of 100 mm3.937 infrom the front surface of the air flow outlet and a pressure of 0.25 MPa while the shower nozzle is in use. (Measured on a sample left in the atmosphere at a relative humidity of 65 % RH or less for 24 hours or more.) |
| Vérifier la sortie (VÉRIFIER) | NPN open-collector transistor• Maximum sink current: 50 mA• Applied voltage: 30 V DC or less (between check output and 0 V)• Residual voltage: 1 V or less (at 50 mA sink current) |
| Consommation de courant | 70 mA or less |
| Entrée de réinitialisation (RESET) | When abnormal discharge is detected, discharge is halted due to an error. Reset the discharge halt by briefly shorting thepower supply’s 0 V line. |
| résistance aux vibrations | 10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude in X, Y and Z directions for two hours each |
| Tension de sortie de décharge | 2,000 V approx. |
| Indicateurs : Vérifier (VÉRIFIER) | Orange LED (lights up when the discharge needle is worn or dirty, etc.)(Note) When confirming the check output, carry out discharge for 2 sec. or more. |
| Indicateurs : Erreur (ERREUR) | Red LED (lights up when abnormal discharge is detected) |
| Indicateurs : Alimentation (POWER) | Green LED (lights up when the power is ON) |
| Indicateurs : Décharge (DSC) | Green LED (lights up when discharging)\n(Note: ”DSC” is an abbreviated name of ”DISCHARGE”.) |
| Vérifier la sortie : Opération de sortie | ON when a dirt or worn etc. of the discharge needle is detected for 1.5 sec. or more continuously, OFF when operation is normal(Note) When confirming the check output, carry out discharge for 2 sec. or more. |
| Sortie d'erreur : Opération de sortie | OFF when abnormal discharge is detected, ON when operation is normal |
| Entrée d'arrêt de décharge (DSC OFF) | Short-circuit to 0 V: Discharge halt, Open: Discharge allowed (operation start)\n(Note: ”DSC” is an abbreviated name of ”DISCHARGE”.) |
| Vérification de la sortie : protection contre les courts-circuits | Incorporated |
| Sortie d'erreur : Protection contre les courts-circuits | Incorporated |