| Paramètre | Valeur |
|---|---|
| Article | Specifications |
| Poids | Net weight : 410 g approx. |
| Détails | Head |
| Produit | Pulse AC Method Area Ionizer |
| Matériel | Main unit enclosure: PPS, Stainless steal (SUS)Head mounting bracket: Stainless steal (SUS), Discharge needle: Tungsten |
| Équilibre ionique | plus or minus 30 V or less(Note: In condition of discharge distance 100 mm 3.937 in, center of the product, discharge wavelength 50 Hz and no air supply.)(Note: Ion balance is average of plus and minus. Also, the specification value is typical value in condition of less than plus or minus 10 degrees ambient temperature change, set the ion balance after 30 minutes of the discharge starting, switching on the ion balance control function.) |
| Numéro de pièce | ER-X016 |
| Nom du produit | Pulse AC Method Area Ionizer ER-X |
| Numéro de produit | ER-X016 |
| Humidité ambiante | 35 to 65 % RH, Storage: 35 to 85 % RH |
| Fluide applicable | Air (dried clean air)(Note:The dried clean air is dried (dew point: equivalent of -20 ℃) and filtered (mesh-size: equivalent of 0.01 micro m) air.) |
| Méthode de décharge | Pulse AC method |
| génération d'ozone | 0.01 ppm or less |
| résistance aux chocs | 100 m/s2 acceleration (10 G approx.), in X, Y and Z directions three times each |
| Mise à la terre du boîtier | Floating |
| Altitude opérationnelle | 2,000 m6561.68 ftor less(Note:Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.) |
| Température ambiante | 0 to +50 °C +32 to +122 °F (No dew condensation), Storage: -10 to +65 °C +14 to +149 °F |
| délai de retrait des frais | 1 second or less(Note: In condition of discharge distance 100 mm 3.937 in, center of the product, discharge wavelength 50 Hz and no air supply.) |
| Fréquence de décharge | 100 Hz / 70 Hz / 50 Hz / 30 Hz / 20 Hz / 10 Hz / 5 Hz / 1 Hz(Note: The high-voltage cable is also available in lengths of 1 m3.281 ftand 2 m6.562 ft. The discharge frequency of 1 m3.281 ft/ 2 m6.562 ftcables is 50 / 30 / 20 / 10 / 5 / 1 Hz. For details, please contact our sales office.) |
| Pression atmosphérique maximale | 0.5 Mpa |
| résistance aux vibrations | 10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude in X, Y and Z directions for two hours each |
| Réglementation applicable | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), TÜV SÜD certification (USA, Canada) |
| Tension de sortie de décharge | ±7,000 V approx. |
| Longueur du câble haute tension | 0.5 m1.640 ft(Note:The high-voltage cable is also available in lengths of 1 m3.281 ftand 2 m6.562 ft. The discharge frequency of 1 m3.281 ft/ 2 m6.562 ftcables is 50 / 30 / 20 / 10 / 5 / 1 Hz. For details, please contact our sales office.) |
| largeur de décapage efficace | 160 mm 6.299 in approx. |