| Paramètre | Valeur |
|---|---|
| Article | Specifications |
| Poids | Net weight : 130 g approx. |
| Détails | Controller |
| Produit | Pulse AC Method Area Ionizer |
| Matériel | Enclosure: ABS |
| Indicateurs | Displays status of Head 1 and 2 |
| Accessoires | Power supply / I/O connector: 1 set (Housing 5557-10R, Terminal 5556TL [manufactured by Molex])Ground wire (3.7 m 12.139 ft approx.): 1 pc. |
| Numéro de pièce | ER-XC02 |
| Nom du produit | Pulse AC Method Area Ionizer ER-X |
| Numéro de produit | ER-XC02 |
| Tension d'alimentation | 24 V DC ±10 % |
| Humidité ambiante | 35 to 65 % RH, Storage: 35 to 85 % RH |
| résistance aux chocs | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each |
| Mise à la terre du boîtier | Floating |
| Température ambiante | 0 to +50 °C +32 to +122 °F (No dew condensation),Storage: -10 to +65 °C +14 to +149 °F |
| Consommation de courant | 450 mA or less when connecting 1 heads, 800 mA or less when connecting 2 heads |
| Indicateur : jauge de niveau | Green LED (5 levels, lights up depending on amount of the charge or ion generation) |
| résistance aux vibrations | 10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude in X, Y and Z directions for two hours each |
| résistance d'isolation | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Réglementation applicable | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), TÜV SÜD certification (USA, Canada) |
| Indicateurs : Vérifier (VÉRIFIER) | Orange LED (lights up when dirt, wear, etc. of the discharge needle is detected) |
| Indicateurs : Erreur (ERREUR) | Red LED (lights up when abnormal discharge is detected) |
| tenue en tension | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Nombre de têtes connectées | Maximum 2 units |
| Indicateurs : Décharge (DSC) | Green LED (lights up when discharging) |
| Entrée de commande de décharge (DSC OFF) | Discharge allowed: Open,Discharge halt: 24 V or 0 V shorted |
| Sortie[ALARME, ERREUR, COM(Commun)] | PhotoMOS relay output• Maximum load current: 100 mA• Applied voltage: 30 V DC or less (between output-output common)• Residual voltage: 1.5 V or less (at load current of 100 mA) |
| Sortie[ALARM, ERROR, COM (Commun)] : Opération de sortie | ALARM:ON when dirt or wear of the discharge needle is detected;OFF when operation is normal.ERROR:OFF when abnormal discharge is detected;ON when operation is normal. |
| Sortie [ALARME, ERREUR, COM (Commun)] : Protection contre les courts-circuits | Incorporated (automatic reset type) |
Spécifications techniques et données de performance
Guide d'installation et d'utilisation