| Paramètre | Valeur |
|---|---|
| Article | Specifications |
| Câble | 0.1 mm23-core PVC cabtyre cable, 2 m6.562 ftlong |
| Sortir | PNP open-collector transistor- Maximum source current: 50 mA- Applied voltage: 30 V DC or less (between output and +V)- Residual voltage: 1.0 V or less (at 50 mA source current), 0.4 V or less (at 16 mA source current) |
| Détails | General purpose |
| Produit | Leak Detection Sensor |
| Matériel | Enclosure: Polypropylene |
| Protection | IP67 (IEC) |
| Numéro de pièce | EX-F71-PN |
| Nom du produit | Leak Detection Sensor EX-F70/EX-F60 |
| temps de réponse | 50 ms or less |
| Numéro de produit | EX-F71-PN |
| Objet de détection | Water, Fluorinert™Note:Highly viscous liquid may not be detected stably.Note:Fluorinert is the world wide trademark of 3M. |
| Tension d'alimentation | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less |
| rallonge de câble | Extension up to total 50 m164.042 ft |
| Indicateur de défaut | Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly) |
| Humidité ambiante | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Élément émetteur | Infrared LED (non-modulated) |
| Indicateur NORMAL | Green LED (lights up when the sensor is mounted properly) |
| Éclairage ambiant | Incandescent light: 1,000 ℓx or less at the light-receiving face |
| Température ambiante | -10 to +60 ℃+14 to +140 ℉(No dew condensation or icing allowed), Storage: -20 to +70 ℃- 4 to +158 ℉Note : Liquid being detected should also be kept within the rated ambient temperature range. |
| Consommation de courant | 10 mA or less(PNP output type: 15 mA or less) |
| Sortie : Opération de sortie | In normal state: ON, When leak detected or the sensor is mounted improperly: OFF |
| Sortie : Protection contre les courts-circuits | Incorporated |