Heures de service : Lundi à vendredi 9h00-18h00
UEXL212 - UEXL212 EX-L212 PANASONIC Laser Trough beam, 3m, spot 8x5,5mm, NPN, cable 2m
En stock Produit phare

UEXL212

UEXL212 EX-L212 PANASONIC Laser Trough beam, 3m, spot 8x5,5mm, NPN, cable 2m

$0.00USD
3951 en stock
Spécifications clés
Article:Specifications
Câble:0.15 mm24-core (emitter of a thru-beam type: 2-core) cabtyre cable, 2 m6.562 ftlong
Sortir:NPN open-collector transistor- Maximum sink current: 50 mA- Applied voltage: 26.4 V DC or less (between output and 0 V)- Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current)
Poids:Net weight: Emitter: 40 g approx., Receiver: 40 g approx.,Gross weight: 90 g approx.
Informations sur le fournisseur
PANASONIC
PANASONIC
Produits : 4316
Habituellement expédié sous 2 à 3 jours ouvrables
Qualité garantie
Livraison rapide
Support technique

Spécifications techniques

ParamètreValeur
ArticleSpecifications
Câble0.15 mm24-core (emitter of a thru-beam type: 2-core) cabtyre cable, 2 m6.562 ftlong
SortirNPN open-collector transistor- Maximum sink current: 50 mA- Applied voltage: 26.4 V DC or less (between output and 0 V)- Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current)
PoidsNet weight: Emitter: 40 g approx., Receiver: 40 g approx.,Gross weight: 90 g approx.
DétailsThru-beam type
ProduitAmplifier Built-in Ultra-compact Laser Sensor
MatérielEnclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate
AccessoireMS-EXL2-2 (Mounting plate): 2 pcs.
ProtectionIP67 (IEC)
Numéro de pièceEX-L212
Nom du produitAmplifier Built-in Ultra-compact Laser Sensor EX-L200
RépétabilitéPerpendicular to sensing axis: 0.05 mm0.0020 inor less
temps de réponse0.5 ms or less
Portée de détection3 m9.843 ft
Numéro de produitEX-L212
Objet de détectionOpaque object of ø3 mmø0.118 inor more
Tension d'alimentation12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Indicateur de puissance-
Humidité ambiante35 to 85 % RH, Storage: 35 to 85 % RH
Élément émetteurRed semiconductor laser Class 1 (IEC / JIS/ FDA/ GB/ EN/ KS) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration)(Maximum output: 1 mW, Peak emission wavelength: 655 nm0.026 mil)
résistance aux chocs500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each
Éclairage ambiantIncandescent light: 3,000 lx or less at the light-receiving face
Température ambiante-10 to +55 ℃+14 to +131 ℉(No dew condensation or no icing condition),Storage: -30 to +70 ℃-22 to +158 ℉
Consommation de courantEmitter: 10 mA or lessReceiver: 10 mA or less
Indicateur de fonctionnementOrange LED (lights up when the output is ON) (incorporated on the receiver for thru-beam type)
Indicateur de stabilitéGreen LED (lights up under stable light received condition or stable dark condition) (incorporated on the receiver for thru-beam type)
Réglage de la sensibilité-
résistance aux vibrations10 to 500 Hz frequency, 1.5 mm0.059 indouble amplitude (10 G max.) in X, Y and Z directions for two hours each
résistance d'isolation20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
Conformité réglementaireCE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Sortie : Opération de sortieLight-ON / Dark-ON selectable by the output operation switching input
tenue en tension1,000 V AC for one min. between all supply terminals connected together and enclosure
Taille du point d'émission (typique)Approx. 8 × 5.5 mm0.315 × 0.217 in(vertical × horizontal)(at a sensing distance of 1 m)(Note) In the case sensing distance is 3 m9.843 ft, the emission spot size is H 17 × W 11 mmH 0.669 × W 0.433 in(visual reference value).
Sortie : Protection contre les courts-circuitsIncorporated (short-circuit protection / inverse polarity protection)
Objet de détection minimal (typique)-
Répétabilité (typique) (perpendiculaire à l'axe de détection)-

Description du produit

Digital laser barrier, detection range 3m, spot 8x5.5mm, NPN, cable 2m, IP67, no sensitivity adjustment
Caractéristiques principales
  • Qualité de niveau industriel
  • Conforme RoHS
  • Certifié CE
  • Garantie d’un an

Documents du produit

Fiche technique

Spécifications techniques et données de performance

Manuel d'utilisateur

Guide d'installation et d'utilisation

Top