| Paramètre | Valeur |
|---|---|
| Article | Specifications |
| Câble | 0.15 mm24-core (emitter of a thru-beam type: 2-core) cabtyre cable, 2 m6.562 ftlong |
| Sortir | PNP open-collector transistor- Maximum source current: 50 mA- Applied voltage: 26.4 V DC or less (between output and +V)- Residual voltage: 2 V or less (at 50 mA source current), 1 V or less (at 16 mA source current) |
| Poids | Net weight: 45 g approxGross weight: 60 g approx |
| Détails | Spot reflective type |
| Produit | Amplifier Built-in Ultra-compact Laser Sensor |
| Matériel | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate |
| Accessoire | MS-EXL2-3 (Mounting plate): 1 pc. |
| Hystérèse | 20 % or less of operation distance |
| Protection | IP67 (IEC) |
| Numéro de pièce | EX-L221-P |
| Nom du produit | Amplifier Built-in Ultra-compact Laser Sensor EX-L200 |
| Répétabilité | Perpendicular to sensing axis: 0.05 mm0.0020 inor less |
| temps de réponse | 0.5 ms or less |
| Portée de détection | 45 to 300 mm1.772 to 11.811 in(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm3.937 x 3.937 in) as the object. |
| Numéro de produit | EX-L221-P |
| Objet de détection | ø1 mmø0.039 inor less(at a sensing distance of 300 mm) |
| Tension d'alimentation | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| rallonge de câble | Extension up to total 50 m164.042 ftis possible with 0.3 mm2, or more, cable. |
| Humidité ambiante | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Élément émetteur | Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB/ EN/ KS) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration)(Maximum output: 2 mW, Peak emission wavelength: 655 nm0.026 mil) |
| résistance aux chocs | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Éclairage ambiant | Incandescent light: 3,000 lx or less at the light-receiving face |
| Température ambiante | -10 to +55 ℃+14 to +131 ℉(No dew condensation or no icing condition),Storage: -30 to +70 ℃-22 to +158 ℉ |
| Consommation de courant | 15 mA or less |
| Réglage de la sensibilité | Continuously variable adjuster |
| résistance aux vibrations | 10 to 500 Hz frequency, 1.5 mm0.059 indouble amplitude (10 G max.) in X, Y and Z directions for two hours each |
| résistance d'isolation | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Conformité réglementaire | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| Sortie : Opération de sortie | Light-ON / Dark-ON selectable by the output operation switching input |
| tenue en tension | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Taille du point d'émission (typique) | ø1 mmø0.039 inor less(at a sensing distance of 300 mm) |
| Sortie : Protection contre les courts-circuits | Incorporated (short-circuit protection / inverse polarity protection) |
| Objet de détection minimal (typique) | Gold wire of ø0.01 mmø0.0004 in(Note)Typical values when the sensitivity adjuster is optimally adjusted. |
| Fonction de prévention automatique des interférences | Incorporated(Two sensors can be mounted close together.) |
| Répétabilité (typique) (perpendiculaire à l'axe de détection) | 0.02 mm0.0008 inor less(at 100 to 200 mm sensing distance)(Note)Typical values when the sensitivity adjuster is optimally adjusted. |
Spécifications techniques et données de performance