| Paramètre | Valeur |
|---|---|
| Article | Specifications |
| Câble | 0.15 mm24-core cabtyre cable, 2 m6.562 ftlong |
| Sortir | NPN open-collector transistor- Maximum sink current: 50 mA |
| Poids | Net weight: 45 g approxGross weight: 60 g approx |
| Détails | Convergent reflective type |
| Produit | Amplifier Built-in Ultra-compact Laser Sensor |
| Matériel | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate |
| Accessoire | MS-EXL2-3 (Mounting plate): 1 pc. |
| Hystérèse | 20 % or less of operation distance |
| Protection | IP67(IEC) |
| Numéro de pièce | EX-L262 |
| Nom du produit | Amplifier Built-in Ultra-compact Laser Sensor EX-L200 |
| Répétabilité | Perpendicular to sensing axis: 0.2 mm0.0080 inor less |
| temps de réponse | 0.5 ms or less |
| Portée de détection | 20 to 70 mm0.787 to 2.756 in(Convergent point: 22 mm0.866 in)(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm3.937 x 3.937 in) as the object. |
| Numéro de produit | EX-L262 |
| Objet de détection | Opaque, translucent or transparent object(Note)Make sure to confirm detection with an actual sensor before use. |
| Tension d'alimentation | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| rallonge de câble | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable |
| Humidité ambiante | 35 to 85%RH , Storage: 35 to 85%RH |
| Élément émetteur | Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB/ EN/ KS)(Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).)(Maximum output: 1.3 mW, Peak emission wavelength: 655 nm0.026 mil) |
| Température ambiante | -10 to +55 ℃+14 to +131 ℉(No dew condensation or no icing condition),Storage: -30 to +70 ℃-22 to +158 ℉ |
| Consommation de courant | 15 mA or less |
| Réglage de la sensibilité | Continuously variable adjuster |
| Conformité réglementaire | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| Sortie : Opération de sortie | Light-ON / Dark-ON selectable by the output operation switching input |
| Taille du point d'émission (typique) | Approx. 5 × 1 mm0.197 × 0.039 in(vertical x horizontal)(at a sensing distance of 50 mm) |
| Sortie : Protection contre les courts-circuits | Incorporated (short-circuit protection / inverse polarity protection) |
| Objet de détection minimal (typique) | - |
Spécifications techniques et données de performance
Guide d'installation et d'utilisation