| Paramètre | Valeur |
|---|---|
| Article | Specifications |
| Sortir | NPN open-collector transistor- Maximum sink current: 50 mA- Applied voltage: 26.4 V DC or less (between output and 0 V)- Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) |
| Détails | Retroreflective type |
| Produit | Amplifier Built-in Ultra-compact Laser Sensor |
| Matériel | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate |
| Accessoire | RF-330 (Reflector): 1 pc.MS-EXL2-3 (Mounting plate): 1 pc. |
| Hystérèse | 20 % or less of operation distance |
| Protection | IP67 (IEC) |
| Numéro de pièce | EX-L291-J |
| Nom du produit | Amplifier Built-in Ultra-compact Laser Sensor EX-L200 |
| Répétabilité | Perpendicular to sensing axis: 0.2 mm0.0080 inor less |
| temps de réponse | 0.5 ms or less |
| Portée de détection | 4 m13.123 ft(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm3.937 x 3.937 in) as the object. |
| Numéro de produit | EX-L291-J |
| Objet de détection | Opaque translucent object of ø25 mmø0.984 inor more |
| Tension d'alimentation | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Humidité ambiante | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Élément émetteur | Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB/ EN/ KS) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration)(Maximum output: 0.5 mW, Peak emission wavelength: 655 nm0.026 mil) |
| résistance aux chocs | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Éclairage ambiant | Incandescent light: 3,000 lx or less at the light-receiving face |
| Température ambiante | -10 to +55 ℃+14 to +131 ℉(No dew condensation or no icing condition),Storage: -30 to +70 ℃-22 to +158 ℉ |
| Consommation de courant | 15 mA or less |
| Réglage de la sensibilité | Continuously variable adjuster |
| résistance aux vibrations | 10 to 500 Hz frequency, 1.5 mm0.059 indouble amplitude (10 G max.) in X, Y and Z directions for two hours each |
| résistance d'isolation | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Conformité réglementaire | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| Sortie : Opération de sortie | Light-ON / Dark-ON selectable by the output operation switching input |
| tenue en tension | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Taille du point d'émission (typique) | Approx. 6 × 4 mm0.236 × 0.157 in(vertical x horizontal)(at a sensing distance of 1 m)(Note) In the case sensing distance is 4 m 13.123 ft, the emission spot size is H 18 x W 10 mmH 0.709 x W 0.394 in(visual reference value). |
| Sortie : Protection contre les courts-circuits | Incorporated (short-circuit protection / inverse polarity protection) |
| Objet de détection minimal (typique) | - |
| Fonction de prévention automatique des interférences | Incorporated(Two sensors can be mounted close together.) |
| Répétabilité (typique) (perpendiculaire à l'axe de détection) | - |
Spécifications techniques et données de performance
Guide d'installation et d'utilisation