| Paramètre | Valeur |
|---|---|
| Article | Specifications |
| Sortir | PNP open-collector transistor・Maximum source current: 100 mA・Applied voltage: 30 V DC or less (between output and +V)・Residual voltage: 1.5 V or less (at 100 mA source current)0.4 V or less (at 16 mA source current) |
| Poids | Emitter: 45 g approx., Receiver: 50 g approx. |
| Détails | PNP output |
| Produit | Water Detection Sensor |
| Matériel | Polycarbonate |
| Accessoire | Adjusting screwdriver: 1 pc. |
| Dimensions | W12 x H31 x D20 mmW0.472 x H1.221 x D0.787 in |
| Protection | IP67 (IEC) |
| Numéro de pièce | EZ-11-PN |
| Nom du produit | Water Detection Sensor EZ-10 |
| temps de réponse | 12 ms or less |
| Portée de détection | 5 m16.404 ft(without container or pipe)(Note):The sensing range shortens depending on the thickness, material, color, etc., of the container or pipe. |
| Numéro de produit | EZ-11-PN |
| Objet de détection | ø12 mmø0.472 mmor more liquid which contains water, or opaque object(Note):If there are two slit masks on both sides, the size of those slit masks represents the min. sensing object. |
| Tension d'alimentation | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less |
| Humidité ambiante | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Élément émetteur | Infrared LED (modulated) |
| résistance aux chocs | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Éclairage ambiant | Incandescent light: 3,000 ℓx or less at the light-receiving face |
| Température ambiante | 0 to +55 ℃ +32 to +131℉ (No dew condensation allowed), Storage: -30 to +70 ℃-22 to +158℉ |
| Consommation de courant | Emitter: 25 mA or less, Receiver: 25 mA or less |
| Réglage de la sensibilité | Continuously variable adjuster |
| résistance aux vibrations | 10 to 500 Hz frequency, 3 mm0.118 indouble amplitude (20 G max.) in X, Y and Z directions for two hours each |
| résistance d'isolation | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Sortie : Opération de sortie | Switchable either Light-ON or Dark-ON |
| tenue en tension | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Résultat : Catégorie d'utilisation | DC-12 or DC-13 |
| Conformité à la directive de marquage CE | EMC Directive, RoHS Directive |
| Sortie : Protection contre les courts-circuits | Switchable either Light-ON or Dark-ON |
Spécifications techniques et données de performance