| Paramètre | Valeur |
|---|---|
| Article | Specifications |
| Câble | 0.2 mm2cabtyre cable with M12 connector, 0.3 m0.984 ftlong |
| Remarque | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23℃+73.4℉. |
| Poids | Net weight: 35 g approx., Gross weight: 60 g approx. |
| Matériel | Enclosure, Case cover: Polycarbonate, Switch: Polyacetal |
| Protection | IP40 (IEC) |
| Numéro de pièce | FX-551L3-P-J |
| Nom du produit | Digital Fiber Sensor FX-550L |
| temps de réponse | STD: 250 μs or less, LONG: 2 ms or less, U-LG: 4 ms or less, HYPR: 24 ms or less, selectable |
| Numéro de produit | FX-551L3-P-J |
| Tension d'alimentation | 12 to 24 V DC+10-15% Ripple P-P 10 % or less |
| Fonction de minuterie | Incorporated with variable OFF-delay / ON-delay / One-shot, switchable either effective or ineffective |
| rallonge de câble | Extension up to total 20 m65.617 ftis possible with 0.3 mm2, or more, cable.(Condition of CE compliance: less tan 20 m65.617 ft) (however, supply voltage 12 V DC or more) |
| résistance aux chocs | 98 m/s2acceleration (10 G approx.) in X, Y and Z directions five times each |
| Consommation d'énergie | Normal operation: 960 mW or less (current consumption 40 mA or less at 24 V supply voltage)ECO mode: 720 mW or less (current consumption 30 mA or less at 24 V supply voltage) |
| Température ambiante | -10 to +55℃+14 to +131℉(If 4 to 7 units are mounted in cascade: -10 to +50℃+14 to +122℉or if 8 to 16 units are mounted in cascade: -10 to +45℃+14 to +113℉) (No dew condensation or icing allowed), Storage: -20 to +70℃-4 to +158℉ |
| Sortie de contrôle (DO) | PNP open-collector transistor• Maximum source current: 50 mA• Applied voltage: 30 V DC or less (between output and +V)• Residual voltage: 2 V or less (Note) (at maximum source current)(Note:)In case of using the cable (cable length 2 m6.562 ft). |
| Réglage de la sensibilité | 2-point teaching / Limit teaching / Full-auto teaching / Manual adjustment |
| résistance aux vibrations | 10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude (10 G max.) in X, Y and Z directions for two hours each |
| Réglementation applicable | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| Fonction minuterie : Période de la minuterie | 0.1 to 999.9 ms approx., in units of 0.1 ms approx. |
| Élément émetteur (modulé) | Red LED (Peak emission wavelength: 660 nm 0.026 mil) |
| Réglage de la sensibilité à la lumière incidente | Incorporated, 4 steps |
| Sortie de communication (C/Q) : Débit en bauds | COM3 (230.4 kbps)(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO). |
| Sortie de contrôle (DO) : Fonctionnement de sortie | Switchable either Light-ON or Dark-ON by L/D mode |
| Plage d'affichage de l'intensité lumineuse incidente | STD: 0 to 4,000, LONG: 0 to 8,000, U-LG / HYPR: 0 to 9,999 |
| Sortie de communication (C/Q) : Données de traitement | 4 byte(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO). |
| Sortie de commande (DO) : Protection contre les courts-circuits | Incorporated |
| Sortie de communication (C/Q) : Temps de cycle minimal | 1.0 ms(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO). |
| Sortie de communication (C/Q) : communication IO-Link | IO-Link Specification V1.1(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO). |
| Fonction de prévention des interférences de fréquences différentes | Incorporated (up to 4 units). Note that the response time varies depending on the setting.F-1: 0.8 ms or less, F-2: 0.9 ms or less, F-3: 1.0 ms or less, F-4: 1.7 ms or less(Note:)This function increases the hysteresis. Check the sensing condition when using the function. |