| Paramètre | Valeur |
|---|---|
| Article | Specifications |
| Câble | 0.2 mm23-core cabtyre cable, 2 m328.084 ftlong |
| Sortir | PNP open-collector transistor- Maximum source current: 100 mA- Applied voltage: 30 V DC or less (between output and +V)- Residual voltage: 1 V or less (at 100 mA source current), 0.4 V or less (at 16 mA source current) |
| Poids | Net weight: 85 g approx. |
| Détails | Amplifier [PNP output] |
| Produit | Color Detection Fiber Sensor |
| Matériel | Enclosure: ABSCase cover: PolycarbonateFiber lock lever: PPS |
| Enseignement | Button operation, Switchable either manual-teaching or auto-teaching |
| Accessoire | MS-DIN-3 (Amplifier mounting bracket): 1 pc.Adjusting screwdriver: 1 pc. |
| Tolérance | Adjustable in 16 grades with the tolerance adjuster |
| Indicateurs | Power indicator: Green LED (lights up when the power is ON, blinks during auto-teaching)Operation indicator: Red LED (lights up when the output is ON)* Both blink alternately when a manual teaching error occursBoth blink simultaneously when the output is short-circuited |
| Numéro de pièce | FZ-11P |
| Nom du produit | Color Detection Fiber Sensor FZ-10 |
| temps de réponse | 1 ms or less (3 ms or less when auto-teaching has been engaged) |
| Numéro de produit | FZ-11P |
| Objet de détection | Opaque or translucent object larger than the spot diameter of the applicable fiber(Note) Make sure to confirm detection with an actual sensor before use. |
| Tension d'alimentation | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Fonction de minuterie | Approx. 40 ms fixed OFF-delay timer (switchable either effective or ineffective) |
| rallonge de câble | Extension up to total 100 m328.084 ftis possible with 0.3 mm2, or more, cable. |
| Humidité ambiante | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Élément émetteur | Red LED / Green LED / Blue LED (Peak emission wavelength: 644 nm0.025 mil/ 525 nm0.021 mil/ 470 nm0.019 mil, modulated) |
| résistance aux chocs | 100 m/s2acceleration (10 G approx.) in X, Y and Z directions three times each |
| Fibres applicables | FD-L51, FD-L52, FD-L53, FD-L54 |
| Éclairage ambiant | Incandescent light: 3,000 lx or less at the light-receiving face |
| Température ambiante | -10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed) (Note) , Storage: -20 to +70 ℃-4 to +158 ℉(Note) The amplifier should be used under the ambient temperature of +15 to +35 ℃+59 to +95 ℉when the tolerance adjuster is set from the 1st grade to the 4th grade, which provide fine color resolution. |
| Consommation de courant | 45 mA or less |
| résistance aux vibrations | 10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude in X, Y and Z directions for two hours each |
| résistance d'isolation | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure(Note) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only. |
| Sortie : Opération de sortie | Switchable either Coincident-ON or Incoincident-ON |
| tenue en tension | 1,000 V AC for one min. between all supply terminals connected together and enclosure(Note) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only. |
| Résultat : Catégorie d'utilisation | DC-12 or DC-13 |
| Conformité à la directive de marquage CE | EMC Directive, RoHS Directive |
| Sortie : Protection contre les courts-circuits | Incorporated |
Spécifications techniques et données de performance