| Paramètre | Valeur |
|---|---|
| Article | Specifications |
| Câble | Discrete wire type: 0.2 mm24-core PVC cable, 2 m6.562 ftlongM12 connector type: 0.2 mm24-core PVC cable with connector, 0.3 m0.984 ftlong |
| Remarque | (Note):Supply voltage: 24 V DC, ambient temperature: +20℃+68℉, response time: 10 ms, and analog output value of measurement center distance are used for unspecified measurement conditions. The subject is white ceramics. |
| Poids | 30 g approx. (without cable), 50 g approx. (including cable) |
| Détails | M12 connector type |
| Produit | CMOS Type Micro Laser Distance Sensor |
| Matériel | Enclosure: Aluminum die-cast, Front cover: Acrylic |
| Linéarité | ±0.1 % F.S. |
| Protection | IP67(IEC) |
| Numéro de pièce | HG-C1050L3-P-J |
| source lumineuse | Red semiconductor laser Class 2 [IEC / EN/ JIS / GB / KS / FDA (Note)] Max. output: 1 mW, emission peak wavelength: 655 nm0.026 mil(Note:)This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance with FDA Laser Notice No. 56, except for complying with IEC 60825-1 Ed. 3. |
| Nom du produit | CMOS type Micro Laser Distance Sensor HG-C1000L |
| Diamètre du faisceau | ø70 μm2.756 milapprox. |
| Répétabilité | 30 μm1.181 mil |
| temps de réponse | Switchable between 1.5 ms / 5 ms / 10 ms |
| Sortie de contrôle | PNP open-collector transistor• Maximum source current: 50 mA• Applied voltage: 30 V DC or less (Between control output to +V)• Residual voltage: 1.5 V or less (at 50 mA source current)• Leakage current: 0.1 mA or less |
| Numéro de produit | HG-C1050L3-P-J |
| Tension d'alimentation | 24 V DC ±10 % Ripple P-P 10 % |
| rallonge de câble | Extension up to total 20 m65.617 ftis possible with 0.3 mm2, or more, cable. |
| Plage de mesure | ±15 mm0.591 in |
| Humidité ambiante | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Degré de pollution | 2 |
| résistance aux chocs | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Altitude opérationnelle | 2,000 m6561.680 ftor less |
| Éclairage ambiant | Incandescent light: 3,000 ℓx or less at the light-receiving face |
| Température ambiante | -10 to +45℃-14 to 113℉(No dew condensation or icing allowed), Storage: -20 to +60℃-4 to 140℉ |
| Consommation de courant | 40 mA or less (at 24 V DC supply voltage) |
| résistance aux vibrations | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm0.059 indouble amplitude in X, Y and Z directions for two hours each |
| distance entre les centres de mesure | 50 mm1.969 in |
| Caractéristiques de température | 0.03%F.S./℃ |
| Sortie de contrôle : Opération de sortie | Switchable between either Light-ON or Dark-ON |
| Sortie de communication (C/Q) : Débit en bauds | COM3 (230.4 kbps) |
| Sortie de contrôle : Protection contre les courts-circuits | Incorporated (auto reset type) |
| Réglementations et certifications applicables | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), FDA Regulations, UL/c-UL Certification |
| Sortie de communication (C/Q) : Données de traitement | 4 byte |
| Sortie de communication (C/Q) : Temps de cycle minimal | 1.0 ms |
| Sortie de communication (C/Q) : Communication IO-Link | IO-Link Specification V1.1 |
Spécifications techniques et données de performance