| Paramètre | Valeur |
|---|---|
| Article | Specifications |
| Remarque | Where measurement conditions have not been specified precisely, the conditions used were as follows: standard type measurement probe (HG-SS10C), ambient temperature +20 ℃+68 ℉, and a clean atmosphere where dust and liquids such as water and oil do not come in contact with the equipment. |
| Accident vasculaire cérébral | 32.5 mm1.280 inor more |
| Poids | Net weight: 150 g approx. |
| Détails | 32 mm1.260 intypeGeneral purpose Standard type |
| Produit | Contact-Type Digital Displacement Sensor |
| Matériel | Body: Aluminum, Holder: Stainless steel, Spindle: Free-cutting steel, Probe※: Brass (body) / Ceramic (ball), Rubber bellows: NBR (black)※The probes (optional) are also available. |
| Accessoire | Sensor head fastening wrench 1 pc., Mounting nut 1 pc. |
| Résolution | 0.5 μm0.020 mil |
| Numéro de pièce | HG-S1032 |
| Nom du produit | Contact-Type Digital Displacement Sensor HG-S |
| Taux d'échantillonnage | 1ms |
| Numéro de produit | HG-S1032 |
| Plage de mesure | 32mm1.260 in |
| Méthode de mise à la terre | Capacitor grounding |
| Degré de pollution | 2 |
| Fonction de remplacement à chaud | Incorporated |
| Altitude opérationnelle | 2,000 m6561.68 ftor less(Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. |
| Indicateur de fonctionnement | 2-color LED (Orange / Green) |
| Écart de pourboire | 40 μm1.575 mil(typical)(Note):Linearity F.S. = 16 mA, and is linearity with respect to digitally measured values. |
| Contrôleur applicable | HG-SC101(-P), HG-SC111(-P), HG-SC112(-P), HG-SC113 |
| résistance d'isolation | 100 MΩ or more at 250 V DC |
| Conformité réglementaire | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| Précision de l'indication (PP) | Full range: 3.0 μm0.118 milor lessNarrow range: 2.0 μm0.079 milor less(any 60 μm2.362 mil) |
| méthode de détection de position | Optical absolute linear encoder method |
| Force de mesure : montage latéral | 2.53 N or less1.50 N(Note 1): Typical value near center of measurement. |
| Force de mesure : Montage vertical | 2.09 N or less1.19 N(Note): Typical value near center of measurement. |
| Force de mesure : Montage vers le bas | 2.97 N or less1.90 N(Note): Typical value near center of measurement. |
| Résistance environnementale : Protection | IP67 (IEC)(Note): Excludes damage and deterioration to rubber bellows due to external causes. |
| Résistance environnementale : humidité ambiante | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Résistance environnementale : Résistance aux chocs | 1,960 m/s2acceleration in X, Y and Z directions three times each |
| Résistance environnementale : Température ambiante | -10 to +55 ℃+14 to +131 ℉(No condensation or icing),Storage: -20 to +60 ℃-4 to +140 ℉ |
| Résistance environnementale : Résistance aux vibrations | 10 to 150 Hz frequency, 3 mm0.118 indouble amplitude (maximum acceleration 196 m/s2) in X, Y and Z directions for two hours each |