Heures de service : Lundi à vendredi 9h00-18h00
UHGS1110AC - UHGS1110AC HG-S1110-AC PANASONIC HG-S Sensor for measurement by contact. Head sensor with pneumatic actuator..
En stock Produit phare

UHGS1110AC

UHGS1110AC HG-S1110-AC PANASONIC HG-S Sensor for measurement by contact. Head sensor with pneumatic actuator..

$0.00USD
4607 en stock
Spécifications clés
Article:Specifications
Remarque:Where measurement conditions are not specified, the conditions used were as follows: standard type measurement probe (HG-SS10C), ambient temperature of +20 ℃+68 ℉, and a clean atmosphere where water, oil, other liquids or dust does not come in contact with the equipment.
Accident vasculaire cérébral:10.5 mm0.413 inor more(Note) : The position that represents "0" as an absolute value is a position where the spindle is pushed further down from the bottom dead point by 0.1 mm0.004 inor more. The term "stroke" indicates the total stroke length from the bottom dead point to the top dead point.
Poids:Net weight: 80 g approx.
Informations sur le fournisseur
PANASONIC
PANASONIC
Produits : 4316
Habituellement expédié sous 2 à 3 jours ouvrables
Qualité garantie
Livraison rapide
Support technique

Spécifications techniques

ParamètreValeur
ArticleSpecifications
RemarqueWhere measurement conditions are not specified, the conditions used were as follows: standard type measurement probe (HG-SS10C), ambient temperature of +20 ℃+68 ℉, and a clean atmosphere where water, oil, other liquids or dust does not come in contact with the equipment.
Accident vasculaire cérébral10.5 mm0.413 inor more(Note) : The position that represents "0" as an absolute value is a position where the spindle is pushed further down from the bottom dead point by 0.1 mm0.004 inor more. The term "stroke" indicates the total stroke length from the bottom dead point to the top dead point.
PoidsNet weight: 80 g approx.
DétailsAir-driven type10 mm0.394 intype High precision
ProduitContact-Type Digital Displacement Sensor
MatérielBody: Zinc, Holder: Stainless steel, Spindle: Tool steel, Probe (Note): Brass (body) / Ceramic (ball),, Air tube clamp: S60CM(Note) : The probe is also available as an option.
AccessoireSensor head fastening wrench: 1 pc., Mounting nut: 1 pc., Seal cap: 1pc, Air tube clamp: 1 pc.
Résolution0.1 μm0.004 mil
Numéro de pièceHG-S1110-AC
Nom du produitContact-Type Digital Displacement Sensor HG-S
Fluide utilisableClean air (Dew point temperature: -10 ℃+14 ℉or less)
Taux d'échantillonnage1 ms
Numéro de produitHG-S1110-AC
Tube applicableOutside diameter: ø4 mmø0.157 in/ Inside diameter: ø2.5 mmø0.098 in
Force de mesure・Measuring force changes with the air pressure used. Removing the seal cap enables the product to be used as the low measuring force type.・For the relationship between supplied air pressure and measuring force or between measuring force and pushed spindle position, see the figures below. For upward mount without a seal cap, subtract 0.2 N from the measuring force. For side mount, subtract 0.1 N from the measuring force. The following figures are only typical examples, and these relationships differ depending on the assembly accuracy of the product or the abrasion status of sealing materials.
Plage de mesure10 mm0.394 in(Note) : The position that represents "0" as an absolute value is a position where the spindle is pushed further down from the bottom dead point by 0.1 mm0.004 inor more. The term "stroke" indicates the total stroke length from the bottom dead point to the top dead point.
Méthode de mise à la terreCapacitor grounding
Degré de pollution2
Fonction de remplacement à chaudIncorporated
Altitude opérationnelle2,000 m6561.68 ftor less(Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
Indicateur de fonctionnementEquipped (2-color LED: Orange / Green)
Écart de pourboire35 μm1.378 mil(typical value)
Contrôleur applicableHG-SC101(-P), HG-SC111(-P), HG-SC112(-P), HG-SC113(Note) : Be sure to use the sensor in combination with an HG-SC□ controller manufactured in or after February 2019.
résistance d'isolation100 MΩ or more at 250 V DC
Conformité réglementaireCE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Plage de pression de service0.14 to 0.16 MPaWith no seal cap mounted : 0.035 to 0.045 MPa
Précision de l'indication (PP)Full range: 1.0 μm0.039 milor lessLimited range: 0.5 μm0.02 milor less(any 60 μm2.362 mil)
méthode de détection de positionOptical absolute linear encoder method
Capacité à résister à la pression0.2 MPa
Résistance environnementale : ProtectionIP67 (IEC)With no seal cap mounted : -(Note) : Protective structure is not applicable when the sealing portions have deteriorated or become damaged. The protection level is zero when the seal cap is removed.
Résistance environnementale : humidité ambiante35 to 85 % RH, Storage: 35 to 85 % RH
Résistance environnementale : Résistance aux chocs1,960 m/s2acceleration in X, Y, and Z directions three times each
Résistance environnementale : Température ambiante-10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed),Storage: -20 to +60 ℃-4 to +140 ℉
Résistance environnementale : Résistance aux vibrations10 to 500 Hz frequency, 3 mm0.118 indouble amplitude (10 to 58 Hz), maximum acceleration 196 m/s2, (58 to 150 Hz) in X, Y, and Z directions for two hours each

Description du produit

HG-S - Contact measurement sensor. Sensor head with pneumatic actuator. Resolution 0.1μm. Precision 1μm. Range 10mm
Caractéristiques principales
  • Qualité de niveau industriel
  • Conforme RoHS
  • Certifié CE
  • Garantie d’un an

Documents du produit

Fiche technique

Spécifications techniques et données de performance

Manuel d'utilisateur

Guide d'installation et d'utilisation

Top