Heures de service : Lundi à vendredi 9h00-18h00
UHGTC101 - UHGTC101 HG-TC101 PANASONIC HG-T Laser Displacement Sensor. High functionality master controller, NPN output
En stock Produit phare

UHGTC101

UHGTC101 HG-TC101 PANASONIC HG-T Laser Displacement Sensor. High functionality master controller, NPN output

$0.00USD
4052 en stock
Spécifications clés
:When communication unitis connected
Article:Specifications
Câble:0.2 mm22-core (brown and blue lead wires) / 0.15 mm27-core composite cable, 2 m6.562 ftlong
Détails:Master unit / High performance type
Informations sur le fournisseur
PANASONIC
PANASONIC
Produits : 4316
Habituellement expédié sous 2 à 3 jours ouvrables
Qualité garantie
Livraison rapide
Support technique

Spécifications techniques

ParamètreValeur
When communication unitis connected
ArticleSpecifications
Câble0.2 mm22-core (brown and blue lead wires) / 0.15 mm27-core composite cable, 2 m6.562 ftlong
DétailsMaster unit / High performance type
ProduitController
MatérielCase: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal
Poids net140 g approx.
Numéro de pièceHG-TC101
1 à 7 unités1 to 6 units
Nom du produitThru-beam Type Digital Displacement Sensor HG-T
8 à 15 unités7 to 14 units
Gamme d'affichage-199.999 to 199.999 mm-7.874 to 7.874 in
Taux d'échantillonnage1 ms (standard sampling) / 0.5 ms (high-speed sampling)
Numéro de produitHG-TC101
Tension d'alimentation24 V DC ±10 %, including ripple 0.5 V (P-P)
Degré de pollution2
Résolution d'affichage1 μm0.039 mil
Altitude opérationnelle2,000 m6561.68 ftor less(Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
Consommation de courant100 mA or less (when sensor head is connected)(Note) : Current consumption does not include analog current output.
Conformité réglementaireCE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Tête de capteur applicableHG-T1010、HG-T1110
commutation d'entrée externeInput 1, Input 2, and Input 3 can be switched to "Preset / Reset / Trigger", "Bank Input A / Bank Input B / Select (Preset, Reset, Trigger)", or "Laser emission stop".
commutation de sortie externeOutput 1, Output 2, and Output 3 can be switched to 3-value, 2-value, Logic, and Logic 2.
Nombre moyen (temps de réponse)1 time (2 ms), 2 times (3 ms), 4 times (5 ms), 8 times (9 ms), 16 times (17 ms), 32 times (33 ms), 64 times (65 ms), 128 times (129 ms), 256 times (257 ms), 512 times (513 ms), and 1,024 times (1,025 ms) switching type(Note) : Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling).
Nombre d'unités esclaves connectéesMaximum sink current and sourcecurrent of control output
Fonction de prévention des interférencesIncorporated(Note) : This function operates for each set of 4 connected controllers.
Résistance environnementale : ProtectionIP40(IEC)
Sortie analogique : Sortie de courant analogique•Current output range: 4 to 20 mA/F.S. (default value)•Linearity: ±0.25 % F.S.•Output when alarm occurs: 0 mA•Load impedance: 250 Ω max.(Note) : Linearity is a value calculated from digitally measured values at F.S. = 16 mA for current output or F.S. = 4 V for voltage output.
Sortie analogique : Sortie de tension analogique•Voltage output range: 1 to 5 V/F.S. (default value)•Linearity: ±0.05 % F.S.•Output when alarm occurs: 5.2 V•Output impedance: 100 Ω max.(Note) : Linearity is a value calculated from digitally measured values at F.S. = 16 mA for current output or F.S. = 4 V for voltage output.
Entrée externe (Entrée 1, Entrée 2, Entrée 3)Non-contact input or NPN open-collector transistor•Input conditionsInvalid: +8 V to +V DC or open, Valid: 0 to +1.2 V DC•Input impedance: 10 kΩ approx.Non-contact input or PNP open-collector transistor•Input conditionsInvalid: 0 to +0.6 V DC or open, Valid: +4 V to +V DC•Input impedance: 10 kΩ approx.
Nombre maximal de contrôleurs connectablesUp to 15 slave units can be connected to a master unit.(Note) : When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit.
Résistance environnementale : humidité ambiante35 to 85 % RH, Storage: 35 to 85 % RH
Résistance environnementale : Résistance aux chocs98m/s2acceleration (10 G approx.) in X, Y and Z directions five times each
Sortie de contrôle (Sortie 1, Sortie 2, Sortie 3)NPN open-collector transistor•Maximum sink current: 50 mA (Note)•Applied voltage: 30 V DC or less (between output and 0 V)•Residual voltage: 1.5 V or less (at 50 mA sink current)•Leakage current: 0.1 mA or lessPNP open-collector transistor•Maximum source current: 50 mA (Note)•Applied voltage: 30 V DC or less (between output and +V)•Residual voltage: 1.5 V or less (at 50 mA source current)•Leakage current: 0.1 mA or less(Note) : When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below.Number of connected slave unitsMaximum sink current and sourcecurrent of control outputAmbient temperatureWhen communication unitis connected1 to 7 units1 to 6 units20 mA-10~+45℃+14 to +113 ℉8 to 15 units7 to 14 units10 mA
Résistance environnementale : Température ambiante-10 to +50 ℃+14 to +122 ℉(No dew condensation or icing allowed) (Note), Storage: -20 to +60 ℃-4 to +140 ℉(Note) : When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below.Number of connected slave unitsMaximum sink current and sourcecurrent of control outputAmbient temperatureWhen communication unitis connected1 to 7 units1 to 6 units20 mA-10~+45℃+14 to +113 ℉8 to 15 units7 to 14 units10 mA
Résistance environnementale : Résistance aux vibrations10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude (10 to 58 Hz), Maximum acceleration 49 m/s2(58 to 150 Hz) in X, Y and Z directions for two hours each
Résistance environnementale : Résistance d'isolation20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Résistance environnementale : tenue en tension1,000 V AC for one minute between all supply terminals connected together and enclosure
Entrée externe (Entrée 1, Entrée 2, Entrée 3) : Temps d'entrée• Trigger input: 2 ms or more (ON)• Laser emission stop input, preset input, reset input, bank input A/B(Note): 20 ms or more (ON)(Note) : Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling).
Sortie de contrôle (Sortie 1, Sortie 2, Sortie 3) : Sortie d'alarmeOpen when alarm occurs
Sortie de contrôle (Sortie 1, Sortie 2, Sortie 3) : Sortie de jugementN.O. / N.C. switching type
Sortie de commande (Sortie 1, Sortie 2, Sortie 3) : Protection contre les courts-circuitsIncorporated (automatic reset type)

Description du produit

HG-TC101_Controller_Thru-beam Type Digital Displacement Sensor HG-T_Master unit / High performance type
Caractéristiques principales
  • Qualité de niveau industriel
  • Conforme RoHS
  • Certifié CE
  • Garantie d’un an

Documents du produit

Fiche technique

Spécifications techniques et données de performance

Manuel d'utilisateur

Guide d'installation et d'utilisation